BFT DEIMOS ULTRA BT A 400 Instructions D'installation page 29

Actionneur pour portails coulissants à crémaillère
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 33
TABLE "B" - LOGIC MENU - (logic)
Logic
Defnition
Automatic Clo-
TCA
sing Time
Fast closing
FAST CLS.
STEP-BY-STEP
Step-by-step
movement
MOVEMNT
Pre-alarm
PRE-ALARM
Deadman
HOLD-TO-RUN
Block pulses
IBL OPEN
during opening
Block pulses
IBL TCA
during TCA
Block pulses
IBL CLOSE
during closing
Ice feature
ICE
OPEN IN
Open in other
direction
OTHER DIRECT.
Confguration
of safety input
SAFE 1
SAFE 1.
72
Confguration
of safety input
SAFE 2
SAFE 2.
74
INSTALLATION MANUAL
Cross
De-
out
fault
setting
used
0
Logic not enabled
0
1
Switches automatic closing on
0
Logic not enabled
0
1
Closes 3 seconds after the photocells are cleared before waiting for the set TCA to elapse.
Inputs confgured as Start E, Start I, Ped
0
operate with 4-step logic.
Inputs confgured as Start E, Start I, Ped op-
0
1
erate with 3-step logic. Pulse during closing
reverses movement.
Inputs confgured as Start E, Start I, Ped op-
2
erate with 2-step logic. Movement reverses
with each pulse.
0
The fashing light comes on at the same time as the motor(s) start.
0
1
The fashing light comes on approx. 3 seconds before the motor(s) start.
0
Pulse operation.
Deadman mode.
Input 61 is confgured as OPEN UP.
Input 62 is confgured as CLOSE UP.
1
Operation continues as long as the OPEN UP or CLOSE UP keys are held down.
0
WARNING: safety devices are not enabled.
Emergency Deadman mode. Usually pulse operation.
If the board fails the safety device tests (photocell or safety edge, Er0x) 3 times in a row, the device is
switched to Deadman mode, which will stay active until the OPEN UP or CLOSE UP keys are released.
2
Input 61 is confgured as OPEN UP.
Input 62 is confgured as CLOSE UP.
WARNING: with the device set to Emergency Deadman mode, safety devices are not enabled.
0
Pulse from inputs confgured as Start E, Start I, Ped has efect during opening.
0
1
Pulse from inputs confgured as Start E, Start I, Ped has no efect during opening.
0
Pulse from inputs confgured as Start E, Start I, Ped has efect during TCA pause.
0
1
Pulse from inputs confgured as Start E, Start I, Ped has no efect during TCA pause.
0
Pulse from inputs confgured as Start E, Start I, Ped has efect during closing.
0
1
Pulse from inputs confgured as Start E, Start I, Ped has no efect during closing.
0
The Amperostop safety trip threshold stays at the same set value.
The controller automatically adjusts the obstacle alarm trip threshold at each start up.
Check that the force of impact measured at the points provided for by standard EN 12445 is lower than the
0
value laid down by standard EN 12453. If in doubt, use auxiliary safety devices.
1
This feature is useful when dealing with installations running at low temperatures.
WARNING: once this feature has been activated, you will need to perform an autoset opening and closing
cycle.
0
Standard operating mode (See Fig.S Ref. 1).
0
1
Opens in other direction to standard operating mode (See Fig. S Ref.2)
0
Input confgured as Phot (photocell).
1
Input confgured as Phot test (tested photocell).
0
2
Input confgured as Phot op (photocell active during opening only).
3
Input confgured as Phot op test (tested photocell active during opening only).
4
Input confgured as Phot cl (photocell active during closing only).
5
Input confgured as Phot cl test (tested photocell active during closing only).
6
6
Input confgured as Bar, safety edge.
7
Input confgured as Bar, tested safety edge.
8
Input confgured as Bar 8k2.
Optional extras
step-by-step mov.
2 STEP
3 STEP
CLOSED
OPENS
OPENS
DURING
CLOSING
OPEN
CLOSES
CLOSES
DURING
STOP + TCA STOP + TCA
OPENING
AFTER STOP
OPENS
OPENS
DEIMOS ULTRA BT A 400 - DEIMOS ULTRA BT A 600 -
4 STEP
OPENS
STOPS
CLOSES
OPENS
29

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Deimos ultra bt a 600

Table des Matières