‧ Never put a finger or any object through the slots of the ventila-
tion grille. The contact with the fan propeller can cause injuries.
‧ Only carry out the work described in these instructions.
‧ Protect the mains cable against heat, oil and sharp edges.
‧ Never make technical modifications to the appliance.
‧ Only use original spare parts and accessories for the appliance.
‧ Repairs must only be carried out by an EHEIM service centre.
‧ We recommend protecting all electrical aquarium appliances via
a residual current protective device with a rated residual current
of 30 mA maximum.
‧ If they are not being used, always disconnect all devices in the
aquarium from the power supply before you install/remove any
parts and before all cleaning and maintenance work.
‧ Protect the socket, mains plug and
switching power supply unit from
moisture. A drip loop must be formed
with the mains cable. This prevents
any water running along the cable to
the mains socket, which would result
in a short-circuit.
‧ The electrical data of the appliance
and the switching power supply unit
have to match that of the power grid.
This data is found on the type plate,
the packaging and in these instruc-
tions.
‧ Do not attach multiple sockets or portable power supply units to
the rear of the device.
‧ The device complies with the radio equipment directive
2014/53/EU. The full text of the EU declaration of conformity is
available online here:
www.eheim.com.
‧ Only use the switching power supply unit that has been sup-
plied with the WiFi controller. If it needs to be replaced, then an
original EHEIM switching power supply unit has to be used.
‧ The device contains the flammable coolant R290. Any work with
it has to be performed by experienced expert personnel trained
in the R290 gas managed process.
‧ The cooling circuit must not be damaged.
‧ When disposing of the appliance, proceed as described in the
chapter "Decommissioning and disposal".
Assembly and installation
Unpacking
CAUTION! Material damage.
▶ Take into account the weight of the device. Always use the
recessed grips to carry the device.
Preserve the packaging for a safe future storage or transporta-
tion.
1. Open the packaging and remove the accessories.
2. Use the recessed grips to pull the device upwards and out of
the packaging.
3. Remove the Styrofoam trays and plastic bags.
4. Ensure that the scope of delivery is complete.
5. Check all components for transport damage.
Installation site
‧ In order to ensure the intended and safe operation of the device, it
must never be exposed to the elements or direct heat sources. The
device can be used in ambient temperatures from 10°C to 38°C.
‧ The device always has to be placed below the water level of the
aquarium. Note that the maximum installation height is 180 cm.
Preparation (⌦E/F)
Aquarium
Placement in the base cabinet of the aquarium or the cabinets
(⌦G/H/I)
Drip Loop
Free-standing placement
Installing the hoses (⌦J/K)
12
1. Place the cover ① onto the climate control unit.
2. Secure the cover with the wrench ② by tightening the screws
on the left and the right a quarter turn clockwise.
3. Connect the WiFi controller ⑤ to the climate control unit with
the RJ45 data cable③.
4. Connect the WiFi controller to the ④ switching power supply
unit.
5. Remove the plugs at the connection IN ⑥ and the connection
OUT ⑦.
Keep the plugs. They can be used as transport protection to
prevent the leaking of residual water.
Maintain a minimum distance of at least 50 mm to the walls and
doors of the cabinet. Keep the ventilation openings free.
1. Choose an even surface for the placement of the device.
2. Saw a section ⑨ of approx. 200 × 200 mm (approx. 400 cm
into the rear wall of the cabinet (for example) in order to ensure
the fresh air supply and the laying of hoses and electrical
installations.
3. Saw a section for receiving the warm exhaust air duct ⑪
into the cabinet ⑩ in order to ensure that the warm air of the
device can leave the cabinet.
‧ Use the self-adhesive template for marking the opening.
‧ We recommend placing the opening for the warm exhaust
air duct in the back wall of the cabinet. This allows the digital
display to be clearly visible from the front. Please note the
dimensions in the following table:
Warm exhaust air duct dimensions
S
T
U
climacontrol+ S
V
climacontrol+ M
climacontrol+ L
4. Following the hose installation, slide the device against the
respective wall and push the warm exhaust air duct onto the
device from behind through the opening.
Maintain a minimum distance of at least 50 mm to walls, furni-
ture, etc. in order to ensure an optimal fresh air supply and the
removal of warm air.
1. Choose an even surface for the placement of the device.
CAUTION! Material damage.
▶ Only operate the device with filtered, clean water.
‧ Take note of the installation examples ⌦B/C/D.
‧ In order to ensure an optimal and efficient circulation perfor-
mance of the filter, we recommend operating aquarium filters
and climate control units with separate water circuits (⌦C).
‧ For a simpler installation, we recommend slightly greasing the
connecting parts with Vaseline.
)
2
260 mm
74 mm
> 60 mm
343 mm
385 mm
427 mm