(3) As shown in Fig 14, fix the bolts at the
blade holder after blade replacement has
been completed.
(4) Turn the cutter block over, and set the
other side in the same manner.
3. Adjustment of carbide blade height:
CAUTION:
If the carbide blade's heights are in-
accurate after above procedures have
been completed, carry out the proce-
dures described below.
(1) As shown in Fig 15, use the box wrench to
loosen the three bolts used to retain the
carbide blade, and remove the blade
holder.
(2) As shown in Fig 16, after removing the
carbide blade, slide set plate (B) in the
direction indicated by the arrow to
disassemble set plate (B).
(3) Loosen the 2 screws holding on the
carbide blade and set plate (A), set plate
(B).
(4) As shown in Fig 17, 18, press the turned
surface of set plate (A) to the wall surface
b while adjusting the carbide blade edge
to the wall surface a of the set gauge.
Then, tighten them with the 2 screws.
Fig. 17
Turned Surface
Machine Screw
Box Wrench
Bolt
Blade Holder
Fig. 14
Box Wrench
Blade Holder
Fig. 15
Fig. 16
Set Plate (B)
Set Plate (A)
Fig. 18
English
Bolt
Set Plate (B)
Carbide Blade
Wall Surface a
Set Gauge
Wall Surface b