WARNING:
Never place your hands, fingers or other body parts near the rotating blades.
Never hold switchlock.
Never carry a tool with a finger on the switch.
CAUTION:
Pull out battery after finished operating, and while taking break.
Never use type EB12M battery, because maybe near terminal is distorted by heat.
Before use, try to cool the battery (above 115°F (45° C)) which became hot immedi-
ately after being charged or stored in a vehicle during transportation. If the battery
is used while still hot, it is likely that the battery case will undergo thermal
deformation or its service life will be shortened.
1. Adjusting the cutting depth:
Turn the knob in the direction indicated
by the arrow in Fig. 6 (clockwise), until the
triangular mark is aligned with the desired
cutting depth on the scale.
An interval between graduations on the
scale corresponds to 1/256" (0.1 mm) in
cutting depth.
The cutting depth can be adjusted within
a range of 0 – 5/256" (0 – 0.5 mm).
2. Operation of switch
(1) For safe operation of the machine, a
"switch lock" is provided on the side of a
handle.
If the "switch lock" is pulled in a state
where it is pressed in the direction of the
arrow mark, the switch can be turned ON.
(2) After the switch is turned ON, even when
you release your hand from the switch
lock, the body continues running as long
as you keep on pulling the switch trigger.
(3) If you release the switch trigger, you can
turn OFF the switch and the "switch lock"
returns
to
automatically. (Fig. 7)
16
the
home
position
Knob
Graduation
Triangular
Mark
Fig. 6
Switch Lock
Switch Trigger
Fig. 7