Troubleshooting - Tanaka TCG 24EBSP SL Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

English

TROUBLESHOOTING

Use the inspections in the table below if the tool
does not operate normally. If this does not remedy
the problem, consult your dealer or the Tanaka
dealer.
Condition
Fuel
system
Engine does not
start
Electrical
system
Other
16
Cause
Fuel tank is empty or fuel level is
low
Fuel tank contains old fuel
(offensive odor)
Too much fuel is absorbed and
spark plug is wet
Fuel fi lter is clogged with dirt
Fuel pipe is bent or disconnected
Carburetor malfunction
Stop switch lead has short-circuited Contact Tanaka dealer
Spark plug is dirty
Electrode gap is too big
Poor connection between high
tension cable and spark plug
Electrical system malfunction
Muffl er exhaust port is clogged with
carbon
Remedy
Fill the fuel tank with the correct fuel
mix (25:1-50:1)
Replace with new fuel
1. Disconnect the spark plug and allow
to dry
2. Pull the starter handle 5 or 6 times
to remove the surplus fuel
3. Attach the spark plug
4. Set the choke lever to RUN position
and pull the starter handle
Clean the fuel fi lter
Ensure that the fuel fl ows smoothly
Contact Tanaka dealer
Replace or clean the spark plug
Adjust the gap to 0.6mm
Reconnect
Contact Tanaka dealer
Contact Tanaka dealer for repair