Technical Data - Ecolab MULTRONIC Manuel Technique

Masquer les pouces Voir aussi pour MULTRONIC:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

9

Technical data

CD module conductive
Measuring ranges
Accuracy
Resolution
Temperature compensation
Calibration
417101802_Anhang02_LF_konduktiv.doc
Conductivity Measuring Module (contact measurement)
0-2 µS, 0-20 µS, 0-200 µS
configurable
< 1% of the final value of the measuring range
1 to 0,001 µS depending on the measurement
range
Manual: 0 - 100 °C
Automatic with Pt100: 0 - 100 °C
Reference temperature 25 °C
Temperature unit °C or °F
Tk-value 0 – 5 %
with calibration box, depending on the measuring
range Auto-read function for stable measured
value
- 52 -
Rev.: 05-07/10

Publicité

Table des Matières
loading

Table des Matières