Hitachi X200 Série Manuel D'utilisation page 270

Masquer les pouces Voir aussi pour X200 Série:
Table des Matières

Publicité

B-26
Code
foncti
on
A020
Multi-speed 0 setting
A220
Multi-speed 0 setting
2nd motor
A021
Multi-speed 1 setting
A022
Multi-speed 2 setting
A023
Multi-speed 3 setting
A024
Multi-speed 4 setting
A025
Multi-speed 5 setting
A026
Multi-speed 6 setting
A027
Multi-speed 7 setting
A028
Multi-speed 8 setting
A029
Multi-speed 9 setting
A030
Multi-speed 10 setting
A031
Multi-speed 11 setting
A032
Multi-speed 12 setting
A033
Multi-speed 13 setting
A034
Multi-speed 14 setting
A035
Multi-speed 15 setting
A038
Jog frequency setting
A039
Jog stop mode
A041
Torque boost select
A241
Torque boost select,
2nd motor
A042
Manual torque boost
value
A242
Manual torque boost
value, 2nd motor
A043
Manual torque boost
frequency adjustment
A243
Manual torque boost
frequency adjustment,
2nd motor
A044
V/f characteristic curve
selection
A244
V/f characteristic curve
selection, 2nd motor
A045
V/f gain setting
A245
V/f gain setting, 2nd
motor
Liste des registres de maintien
Nom
R/W
R/W Defines the first speed of a
multi-speed profile, range is 0.0 /
start frequency to 400 Hz
A020 = Speed 0 (1st motor)
R/W Defines the first speed of a
multi-speed profile, range is 0.0 /
start frequency to 400 Hz
A220 = Speed 0 (2nd motor)
R/W
R/W
R/W
R/W
R/W
R/W
R/W
range is 0.0 / start frequency to
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W Defines limited speed for jog,
range is 0.00 / start frequency
to 9.99 Hz
R/W
stops
the motor; three options:
00...Free-run stop
01...Controlled deceleration
02...DC braking to stop
R/W
Two options:
00...Manual torque boost
R/W
01...Automatic torque boost
R/W
Can boost starting torque
between 0 and 20% above
normal V/f curve,
R/W
range is 0.0 to 20.0%
R/W
Sets the frequency of the V/f
breakpoint A in graph (top of
previous page) for torque boost,
R/W
range is 0.0 to 50.0%
R/W
Two available V/f curves;
two select codes:
R/W
00...Constant torque
01...Reduced torque
06...Reduced torque1
R/W
Sets voltage gain of the inverter,
range is 20. to 100.%
R/W
Description
Defines 15 more speeds,
400 Hz.
A021= Speed 1...
A035 = Speed 15
Define how end of jog
Données du réseau
Registre.
Plage
Résolution
1029h
0 / start
0.1 Hz
freq. to
4000
150Fh
0 / start
0.1 Hz
freq. to
4000
102Bh
0 / start
0.1 Hz
freq. to
102Dh
4000
102Fh
1031h
1033h
1035h
1037h
1039h
103Bh
103Dh
103Fh
1041h
1043h
1045h
1047h
1048h
0 / start
0.01 Hz
freq. to
999
1049h
0, 1, 2
104Ah
0, 1
1510h
104Bh
0 to 200
0.1 %
1511h
104Ch
0 to 500
0.1 %
1512h
104Dh
0, 1, 6
1513h
104Eh
20 to 100
1514h
.
1 %

Publicité

Table des Matières
loading

Table des Matières