14. Changing the valve cartridge

14.1 Lift off the cover plate with a screwdriver.
14.2 Close the flow volume regulator with a hexagon socket key.
g: closed
14.3 Loosen the cover using a hexagon socket key.
14.4 Remove the cover.
Caution!
Push the cover on the casing when reassembling so that the rib (S) locks into the
recess (A). Screw on the cover.
14.5 Separate the line connection between the control unit and valve cartridge.
14.6 Lift out the battery with a screwdriver.
14.7 Remove the battery.
14.8 Remove the battery tray and leave hanging on the outer wall of the upper part of the
flusher.
14.9 Remove the set screw with a hexagon socket key.
14.10 Remove the upper part of the flusher.
14.11 Unscrew the valve cartridge with the assembly key
(Order No.: 2000105836).
Only lightly tighten the set screw (siehe
Kapitel
14.9) for assembly (max. 0.5 Nm).