18. Replacing the Solenoid Valve Cartridge

18.1 Close the corner valves.
18.2 Trigger the valve.
18.3 Loosen the screw (a) with an Allan key.
18.4 Pull the housing (b) from the base (d).
18.5 Pull off the hose sleeve (c).
18.6 Remove the screws (f).
18.7 Remove the battery housing (e).
18.8 Take out and replace the solenoid valve cartridge (g).
18.9 Reassemble in the reverse order.

19. Changing the Battery

19.1 Pull off the housing and the hose sleeve (see
19.2 Remove the battery (a) by swivelling it out.
Caution!
Use only 6 V lithium battery type CRP2.
Important!
Ensure correct battery polarity when assembling.