Electrical Installation

Electrical requirements

You can find the identification plate with the electrical
specifications on the underside of the appliance. The
junction box must be located within 3 feet of the
cooktop connection. It should be easily accessible for
service purposes.
Power supply
10

Connect Electrical Supply

9
CAUTION
Before installing, turn off at the service panel.
Lock service panel to prevent power from being
turned on accidentally.
9
CAUTION
To reduce the risk of electric shock and fire, do
not use a flexible power supply cord.
Refer to data plate for more information. See "Service"
for data plate location.
The branch-circuit breakers ampacity, the wire sizes and
the connections must conform to the requirements of
the National Electrical Code or Canadian Electrical
Code and all local codes and ordinances.
Attach flexible conduit to the junction box. Connect the
lead wires to the junction box supply wires in proper
phase:
black (L1) to black
red (L2) to red
green or bare to ground
1
House power supply cord
2
Black wire
3
Junction box
4
Cooktop power supply cord
5
Grounded green or bare cable
6
Certified UL connector
7
Red wire
If the cooktop is installed and connected as specified
above, it will be completely grounded in compliance with
the National Electrical Code.