Connect Gas Supply; Connect Electrical Supply; Burner Cap Placement - Gaggenau VG491211CA Notice De Montage

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

en-us
Installation Procedure
3.
Only for flush mount installation:
Note: Make sure that everything is working correctly
before grouting.
Grout the surrounding gap with a suitable
temperature-resistant silicone adhesive (e.g.,
OTTOSEAL
S 70). Smooth the joint seal with a
®
smoothing agent recommended by the manufacturer.
Heed the processing instructions for the silicone glue.
Only start up the appliance after the silicone glue is
completely dry (at least 24 hours, depending on the
room temperature).
NOTICE
Unsuitable silicone adhesive causes permanent
discoloration to natural stone countertops.
4.
Connect the appliance to the mains and check that it
works correctly. If the appliance is turned off, air may
be present in the gas line. Turn control knob to 0 and
reignite. Repeat the process until the appliance
ignites.

Connect Gas Supply

The appliance is shipped from the factory for use with
natural gas. It must be converted for use with propane. A
qualified technician or installer must do the conversion.
Before connecting the appliance, please check whether
the local connection conditions such as gas type and gas
pressure match the appliance settings.
Make sure the gas supply is turned off at the manual shut-
off valve before connecting the appliance.
12
All manuals and user guides at all-guides.com
The gas connection must be in a location that permits
access to the manual shut-off valve and which, if
applicable, is visible after opening the door of the
cabinet.
SERVICER INFO ONLY
Connect the gas supply using the ½" U.S.A. elbow and
the fiber gasket supplied with the unit. The shorter,
nontapered thread fits into the threaded nut on the hob.
The longer, tapered U.S.A. thread is for the incoming gas
supply. Vent the gas line, check for leaks. The gas
pressure regulator is supplied with the unit and comes
set for natural gas. To convert regulator to LP (propane)
gas:
Make-Maxitrol Model RV 47 CL ½ PSIG
1.
2.
3.
4.

Connect Electrical Supply

Before connecting supply cord to wall receptacle, make
certain that gas shutoff valve and all burner controls are
in OFF position.
Electrical connection (AC 110-127 V) is established by
means of a connecting cord with a grounding contact
plug connected to a grounded socket, which must also
be accessible after installation of the gas cooktop.

Burner Cap Placement

The burner parts must be properly placed for the cooktop
to function properly. If the burner parts are not properly
placed, one or more of the following problems may occur:
Placing Burner Parts
After electrical connection is complete, assemble the
burner parts correctly and evenly. When assembling the
burner parts, make sure that the burner head is placed on
the base in such a way that the prongs of the burner cap
fit snugly into the groove of the burner base.
Remove the aluminum cap from the top of the
regulator.
Remove the yellow plastic shaft from the cap by
pushing it sideways until it pops out of the groove in
the cap.
Turn the shaft over and push back into the cutout in
the cap.
Replace the cap on the regulator.
Burner flames are too high.
Flames shoot out of burners.
Burners do not ignite.
Burner flames light unevenly.
Burner emits gas odor.

Publicité

Table des Matières
loading

Table des Matières