Télécharger Imprimer la page

tau D750M Notice D'installation page 17

Masquer les pouces Voir aussi pour D750M:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

19 - 20
ELECTRIC LOCK ELECTRIC LOCK power output 12 Vac max. 15 W;
21 - 22
2
RADIO CH
nd
GATE OPEN
23 - 24
WARNING LIGHT
25 - 27
PHOTOCELLS TX
26 - 27
28 - 29
AERIAL
LOGIC ADJUSTMENTS
TRIMMER
R. ANTA
second motor delay adjustment.
T. LAV.
Work Time adjustment.
CH.AUTO
Automatic closing time adjustment.
RALLENT.
adjustment of delay time.
Note: turn the TRIMMER clockwise to increase adjustments; turn it anticlock-
wise to decrease.
Software
R. ANTA
version
(Opening)
1.00 ÷ 1.04
2 - 4 sec.
1.05 ÷ 1.06
2 - 4 sec.
2.07 ÷ 2.12
2 - 4 sec.
3.00 ÷ 3.01
2 - 8 sec.
3.02 ÷ 3.03
2 - 33 sec.*
3.04 ÷ 3.05
1,5 - 6 sec.*
* with Dip Switch 9 in ON, the threshold increases by 3 seconds.
DECELERATION SETTING PROCEDURE
-
Set dip 4 to OFF (deceleration disabled);
-
move the leafs to the closing position;
-
use the trimmer T.LAV. to set the leaf "high speed travel" as required. Check the precise set-
ting by means of a test manoeuvre.
CAUTION: the leaf must not open completely, but has to stop on elapse of the time
previously set on trimmer T.LAV.
-
After returning the leafs to the closing position, enable decel. (dip 4 set to ON).
-
Use the trimmer RALL. to set a time sufficient to complete the opening manoeuvre. At the
end, check the precise setting by means of a test manoeuvre.
NOTE: with RALL. enabled (dip 4 ON), the total travel of the leaf is obtained
from the total of the times set on the two trimmers (T.LAV. + RALLENT.).
2
RADIO CHANNEL output; the output mode can be se-
nd
lected by Dip 7 - 8;
Warning: to connect other devices to the 2nd Radio
Channel (area lighting, pumps, etc.), use an additional
auxiliary relay.
GATE OPEN WARNING LIGHT output; 24 V ac, max 3W;
the light lights with the same frequency as that of the flashing
light for the entire opening and closing manoeuvre and re-
mains on if the gate is open and off when the gate has closed;
24 Vac external transmitting photocell power supply output
for safety device control (connect the external TX photocell
only) max. of 2 photocell transmitters;
24Vac output, 10W for the power supply of photocells, exter-
AUX
nal receivers, etc.
AERIAL input (EARTH=28, SIGNAL=29);
R. ANTA
(Closing)
2 - 10 sec.
2 - 10 sec.
2 - 10 sec.
2 - 16 sec.
2 - 33 sec.
2 - 33 sec.
T.LAV.
RALLENT.
5 - 40 sec.
1/3 T.LAV.
5 - 60 sec.
1/3 T.LAV.
5 - 60 sec.
0 - 30 sec.
5 - 120 sec.
0 - 40 sec.
5 - 120 sec.
0 - 40 sec.
5 - 120 sec.
0 - 40 sec.
D750M
CH. AUTO
2 - 120 sec.
2 - 120 sec.
2 - 120 sec.
2 - 120 sec.
2 - 120 sec.
2 - 120 sec.
17

Publicité

loading