Technical Data Kfa-5 - Rechner Sensors LEVEL KFS-4 Série Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Technical data KFA-5-4-...

Technical data
Electrical version
Output
Type NPN
Connection diagram no.
Type PNP
Connection diagram
Operating voltage (U
Output current max. (I
Permitted residual ripple max.
Power consumption
Permitted ambient temperature
LED-Display
Protective circuit
Norm
Degree of protection IEC 60529
Connection
Wire break
Certificates
Connection diagram:
22
24 V DC
Transistor output /
4 x antivalent
KFA-5-4-...-NPN-A
See below
KFA-5-4-...-PNP-A
See below
)
18...36 V DC
B
)
250 mA each canal
e
Typ. 120 mA
-25...+55° C
Green: U
4 x yellow: level
EN 60947-5-2
Screw terminal /
SMB connectors
CE, RoHS, UL-CSA
Transistor output /
4 x normally open
KFA-5-4-...-NPN-S-FB KFA-5-4-...NPN-Ö-FB
KFA-5-4-...-PNP-S-FB KFA-5-4-...-PNP-Ö-FB
18...36 V DC
250 mA each canal
40 %
stand by /
Green: U
B
4 x yellow: level
Built-in
EN 60947-5-2
IP 54
Screw terminal /
SMB connectors
No
CE, RoHS, UL-CSA
Dimension
24 V DC
4 x normally closed
See below
See below
250 mA each canal
40 %
Typ. 130 mA
-25...+55° C
stand by /
Green: U
B
Built-in
IP 54
Yes
CE, RoHS. UL-CSA
24 V DC
Transistor output /
See below
See below
18...36 V DC
40 %
Typ. 130 mA
-25...+55° C
stand by /
B
4 x yellow: level
Built-in
EN 60947-5-2
IP 54
Screw terminal /
SMB connectors
Yes

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Level kfs-5 série

Table des Matières