2 2 / / INSTALLING YOUR APPLIANCE
• • TIPS FOR FLUSH MOUNTING
Vue de dessous
du carter
Fig. 01
A
A
Patte de fixation
Fig. 02
Place your hob in the opening of the support
cabinet, carefully pulling the table towards
you.
Reposition the burner heads, burner covers
and pan supports on the hob.
Connect your hob to the gas supply (See "Gas
Connection" chapter) and to the power supply
(See "Electrical Connection" chapter).
If you wish, you can immobilise the hob using
the four mounting brackets delivered with a
screw (Fig. 02) to attach them to the four cor-
ners of the housing. Y Y o o u u m m u u s s t t u u s s e e t t h h e e h h o o l l e e s s
p p r r o o v v i i d d e e d d f f o o r r t t h h i i s s p p u u r r p p o o s s e e , , a a c c c c o o r r d d i i n n g g t t o o t t h h e e d d i i - -
a a g g r r a a m m a a b b o o v v e e (Fig. 01) . .
S S t t o o p p s s c c r r e e w w i i n n g g w w h h e e n n t t h h e e m m o o u u n n t t i i n n g g b b r r a a c c k k e e t t
s s t t a a r r t t s s t t o o b b e e c c o o m m e e d d e e f f o o r r m m e e d d . .
D D o o n n o o t t u u s s e e a a s s c c r r e e w w d d r r i i v v e e r r .
A
A
A
Patte de fixation

ELECTRIC CONNECTION

• •
Your hob is sold with a power cable (type
H05V2V2F - T90, cross-section 1 mm
three conductors (phase + ground + neutral).
After-sales service reference: After-sales
service: 77X3767 (6470.1516). It must be con-
nected to a 220-240 V ~ monophase grid via a
standard IEC 60083 electrical outlet with
phase + ground + neutral or or an all-pole
cutoff device, in compliance with current in-
stallation regulations.
The plug of the electrical outlet must be ac-
cessible after installation.
C C
- -
R R O O S S S S
S S E E C C T T I I O O N N O O F F C C A A B B L L E E T T O O B B E E U U S S E E D D
H05V2V2F -T90
cable
Cross-section of the
conductors in mm
Fuse
Warning
The safety wire (green/yellow) is con-
nected to the ground terminal
appliance and must remain connected to
the ground terminal
The fuse in your set-up must be
10 amperes
If the power cable is damaged, it must be
replaced by a cable or a special kit avail-
able from the manufacturer or its After-
Sales Service Department.
Tip
In order to easily locate the refer-
ence information for your appliance, we
recommend that you note it on the "After-
Sales Service Department and Customer
Relations" page. (This page also explains
where to find this information on your
appliance).
30
2
2 2 2 2 0 0 - - 2 2 4 4 0 0 V V ~ ~ - - 5 5 0 0 H H z z
G G a a s s a a n n d d d d u u a a l l
3 conductors
including 1 ground
1
2
10 A
of the
during installation.