WANDERS Kanda Gas Mode D'emploi Et Instructions D'installation page 23

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Placing of the concentric channel sys-
tem
The concentric channel system consists of three parts:
the channels itself, the transit through the roof or through
Instructions for placing the outflow
the roof or against the side wall of the house.
Roof outlet
that there is a distance of at least 50 cm between the
a possible existing ridge. You must also take the place of
tilation openings, movable windows and combustion air
supply provisions. Please consult the national and local
requirements.
Wall outlet
that there is distance of at least 50 cm between the out-
conies and etceteras. You need not have this distance
overhanging part.
in relation to the existing ventilation openings, movable
windows and combustion air supply provisions. Please
consult the national and local requirements.
Placing possibilities of the pipe system
The total length of the pipe system must never be more
than 10 metres excluding the passage through the wall
2 metres. A 45° turn counts as a length of 1 metre.
-
For the combined flue tube and combustion air supply
you must apply one of the following placing possibili-
ties of the WANDERS concentric pipe systems: with wall
duct, with roof duct or with roof duct with bend.
Pay special attention to proper installing when, due to
circumstances, a part of the double-walled pipe system
must be built in.
Wall outlet
through the outer wall.
rior wall duct.
the appliance. Push them firmly together and place
-
the clip bindings. The blue rubber ring ensures suf-
ficient sealing of the discharge system of the waste
gas.
wall, place the vertical one-metre pipe first on the ap-
pliance, then place the curved part, then the exterior
wall duct, and then make them gastight.
Ø 155 mm for the wall duct.
-