Valve Construction; Valve Operations Of The Type 6510 / 6511 Valves; Media - Burkert 6510 Instructions De Service

Masquer les pouces Voir aussi pour 6510:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

T
D
ECHNICAL
ESCRIPTION

Valve Construction

• 3/2 way pilot valve with various electrical connection possibilities
• valve body with diaphragm, seat seal and weldet cover plates
• 2(B) / 4 (A) service ports plus supply and venting ports 1 (P) / 3 (S) / 5 (R), as option with internal
thread or plug-in connectors
• the valves can be mounted on the modular pneumatic basic rail s type MP01 or MP02 to form valve
blocks
• Can be mounted in any position, preferably with the magnetic system at the top
• Manual override for hand operation of the valve
The valves require no maintenance, even for dry-air operation.
NOTE

Valve operations of the Type 6510 / 6511 valves

3/2 way valve:
In de-energised position, Pressure Inlet 1 closed, Outlet Port 2 exhausted
3/2 way valve:
In de-energised position, Pressure Inlet 1 connected to Outlet Port 2
5/2 way valve:
In de-energised position, Pressure Inlet 1 connected to Outlet Port 2, Outlet Port 4 exhausted.

Media

• Filtered compressed air (max. particle size 5 µm), preferably non-oiled
• Operation is possible with oiled air
• Seal materials:
• Permissible medium temperature:
• Permissible ambient temperature:
• Operational pressure range:
ATTENTION!
8 - 6510/6511
NBR and FKM
max. +50° C
max. +55° C
2,5 - 7 bar
For temperatures below 0° C, operation is limited to dry-air operation!