15. EXPERT SETTINGS
15.1. ACCESS TO THE EXPERT SETTINGS
Press
for 5 seconds to enter into the programming mode. The cursor moves to 'setting day and
time'. Press
twice to move to 'User settings'. Press
tings'. Press
and
1
Setting day
and time
5 sec
15.2. SETTING SEQUENCE
All settings are consecutive. To exit the Expert settings, press
1
2
15.2.1. Ambient temperature sensor adjustment
THESE CHANGES SHOULD BE PERFORMED BY QUALIFIED STAFF, IT SHOULD BE PERFORMED
IN PRODUCTION OR ON SITE DURING THE FIRST INSTALLATION.
BEFORE CARRYING OUT THE CALIBRATION IT IS RECOMMENDED TO WAIT FOR 4H AFTER
THE SETING TEMPERATURE MODIFICATION TO INSURE THAT THE AMBIENT TEMPERATURE IS
STABILIZED.
The calibration adjusts the temperature measured by the ambient temperature sensor to compensa-
te for a deviation from + 5°C to - 5°C by intervals of 0.1°C.
1. If the room temperature difference is negative: decrease the temperature measured by the ambi-
ent temperature sensor by pressing
–
Example: setting temperature 20°C, ambient temperature 18°C. Difference is -2°C.
If the room temperature difference is positive: increase the temperature measured by the ambient
temperature sensor by pressing
–
Example: setting temperature 19°C, ambient temperature 21°C. Difference is +2°C.
2. To validate, save the new value and exit the mode, press
86
simultaneaously to enter into the 'Expert settings'
1
Program
settings
1. Ambient temperature sensor adjustment
3
2. Setting the power
3. Restoring factory settings
.
.
for 10 seconds to move to 'Installer set-
User
Installer
settings
10 sec
settings
3 times.
.
Expert
10 sec
settings
simultaneous