19.3.  LEGAL PROTECTIVE ZONE
–  An electrical radiator with insulation class II may be placed in zone A. In bathrooms and kitchens
the socket outlet (never a plug contact) has to be placed at a minimum height of 25cm above the
floor. The radiator may never be installed lower than the adapter socket outlet. A fused spare
has to be used outside the room.
–  In zone B, an electric radiator of insulation class II may be connected to the electricity grid via a
plug contact that is placed in zone B.
–  The appliance must be mounted and connected by an acknowledge installer in accordance with
the installation instructions and national and currently applicable local regulations.
20.  TECHNICAL INFORMATION
20.1.  GENERAL SPECIFICATIONS
–  Operating voltage: 230V +/-10% 50Hz.
–  Maximum power of 1250W, resistive load.
–  Power supply cable: 800mm, 3 Conductors.
–  Heating standby mode consumption: <0,5W.
–  Electronic PID (Proportional Integral Derivative) control, triggered by a triac.
20.2.  SURROUNDINGS
–  IP44 (control panel horizontal oriented after installation).
–  Operating temperature: 0°C to +50°C.
–  Storage temperature: -20°C to +70°C.
–  Comfort temperature setpoint: between +7°C and +30°C approximately.
–  Class II, if correctly installed (according to EN60335-1).
–  NTC (negative temperature coefficient) electronic temperature sensor.