11. Make sure that you do not damage the connection or any other components;
12. Never turn the gas container upside down in order to make full use of the contents. This
may release liquid residues left in the container that damage the heater irreparably;
13. For disconnection or connection of the low-pressure regulator, always follow the user
instructions provided with the regulator;
14. The manufacturer is not responsible for any harm or damage if attention is not paid to the
points described above.
D. Installation
1. Use the gas heater in well-ventilated rooms only. A minimum room size of 85m³ is
recommended for living rooms and 45m³ for other rooms, but the room should never be less
than 15m³. For ventilation, a surface between 12.5m² and 25m² is recommended.
2. The room in which the gas heater is used should have enough air circulation for normal
combustion. Therefore it is recommended that the room must draw at least 100 cm² from the
outside to replace the air;
3. Always place the heater on a flat and stable surface. Never install or use the heater in a
bathroom or bedroom, in the basement, on the upper floors of a building or in leisure
accommodations;
4. Never position the gas heater too close to other sources of heat (a distance of at least 1 metre
is required between the gas heater and other heating sources) or inflammable or explosive
materials.
During operation, the gas heater should not face objects that can be damaged or burned;
5. Position the heater so that the heat is directed towards the center of the room and towards
an open space. In addition, the front, radiant part must be at least 2.0 meter away from any
inflammable materials, i.e. curtains or sofas;
6. Never operate the gas heater when the gas container is outside the compartment.
E. Use
The knobs for turning the gas heater ON are located on the upper part of the heater.
1. Open the gas container (follow the user instructions provided with the low-pressure
regulator).
2. Turn the regulation knob into position 1 as indicated in fig. Press it all the way down and,
at the same time, press the piezoelectric button; this turns the atmosphere analyzer on. To
keep the flame lit, the knob must be held pressed down for 20 seconds after ignition.
1. Minimum and Ignition
2. Medium
3. Maximum
4. Piezoelectric ignition
4
58