Version with air evacuation hole in the upper part
This product is supplied
positioned in the rear part of the hood, as indicated in gure 5 see paragraph: connection
to the electric power supply).
- If a rectangular air outlet pipe is used E, the hood is already set-up Fig.3.1).
- If, ho ever, a circular air outlet pipe is to be used F, the 7 scre s H must be removed along
ith the brac et
Fig.3.2).
Version with air evacuation hole in the rear part
- If your requirements are the use of the air outlet in the rear part of the hood carry out all
phases sho n in gure 2), remove the scre s I Fig. 4.1) that x the motor brac et Y and turn
the entire motor unit and position it as indicated in Fig.4.2. Put the motor brac et Y bac in its
seat and x it ith the previously removed scre s I.
Attention! Whenever a circular air outlet pipe is to be used F, the operation indicated in
Fig.3.2 must al ays be repeated.
For connection to the po er supply refer to the follo ing Fig.5:
1. Brea and remove the small circular metal sheet positioned in the rear part of the hood, ith
the aid of a flat scre driver Fig.5.1.
2. Remove the po er supply lid by loosening the 2 scre s A Fig.5.2.
3. Connect the ires of the hood to those of the po er supply as described Fig.5.3:
BLACK = L line
WHITE = N neutral
G ground
- A double-pole s itch properly rated must be installed to provide the range hood po er
supply disconnection.
- Connect the electrical conduit to the Field Wiring Compartment using listed conduit ttings.
- Carry out the po er supplly connection in accordance
ANSI/NFPA 70-1999.
- Insert the
ires into the box, then close the box cover, securing it using the scre s that
ere previously removed.
OPTIONAL: the electric po er supply box can be removed and xed in the position indicated in Fig.6.
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING Before connecting the appliance to the power supply network,
the electric plant box must be positioned in the seat.
To move the electric power supply box, refer to that indicated in Fig.6:
1. Loosen the t o scre s C Fig.6.1.
2. Brea and remove the small circular metal sheet positioned in the upper part of the hood,
ith the aid of a at scre driver Fig.6.2.
3. Ta e the electric connection box and x it using the 2 scre s C, previously removed, in the
position indicated in Fig.6.3.
4. For the electric power supply connection refer to Fig.5.2-3.
The appliance must be installed at a minimum height of 26 inches 66 cm) from an electric
coo er stove, or 30 inches 76,2 cm) from gas or combined coo er stoves. If a connection
duct or composed of t o parts is used, the upper part must be placed outside the lo er
part. Do not connect the range hood exhaust duct air to the same duct air used to exhaust hot
air or fumes from other appliances other than electrical. Before proceeding ith the assembly
operations, remove the anti-grease lters Fig. 1C) so that the unit is easier to handle.
ith the air outlet in the upper part and the electric connection box