Inspection Checklist; Troubleshooting For Users - Xylem LOWARA ESH ATEX Manuel D'installation, D'utilisation Et Entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 33
en - Original instructions
without forcing as far as it will go.
2.
Make a notch as reference on both half
couplings; see Figure 22.
3.
Rotate the same half coupling in the
opposite direction as far as it will go.
4.
Measure the distance between the two
notches: this will be the torsional
backlash.
Coupling
Maximum permitted
torsional backlash ΔS
size
[mm]
68
5.5
80
5.0
95
6.0
110
7.0
125
8.0
140
8.0
160
8.0
If the torsional backlash exceeds the maximum
permitted limits, contact Xylem or the Authorised
Distributor for the replacement of the coupling.
6.2

Inspection checklist

Check the
Check the flexible elements
coupling
of the coupling. Replace the
relevant parts if there is any
sign of wear and check the
alignment.
Check the
Check for leaks on the
mechanical
mechanical seals; if any are
seal
detected, contact Xylem or
the Authorised distributor.
Checking the
Check correct seating of
bearing seals
axial seal rings mounted on
the shaft. Only gentle
contact of the sealing lip
shall be established.
Check for
Check frequently for quiet
quiet running
running of the pump with
vibration measurements
tools.
6.3 Disassemble and replace the
pump parts
For more information about spare parts and
assembly and disassembly of the pump,
contact Xylem or the Authorised Distributor.
Repair and/or maintenance of the pump must
only be carried out by Xylem or the Authorised
Distributor.
7
Troubleshooting

7.1 Troubleshooting for users

The main switch is on, but the pump unit does
not start.
Cause
The thermal
protector
incorporated in the
pump (if any) has
tripped.
The protective
device against dry
30
V
Solution
Wait until the pump
has cooled down. The
thermal protector will
automatically reset.
Check the liquid level
in the tank, or the
running has
tripped.
The pump unit starts, but the thermal protector
trips a varying time after
Cause
Solution
There are foreign
Contact Xylem or the
objects (solids or
Authorised Distributor.
fibrous
substances) inside
the pump which
have jammed the
impeller.
The pump is
Check the actual
overloaded
power requirements
because it is
based on the
pumping liquid
characteristics of the
that is too dense
pumped liquid and then
and viscous.
contact Xylem or the
Authorised Distributor.
The pump runs but delivers too little or no
liquid.
Cause
Solution
The pump is
Contact Xylem or the
clogged.
Authorised Distributor.
The troubleshooting instructions of the
following tables are only for installation
personnel.
7.2 The main switch is on, but the
pump unit does not start
Cause
Solution
There is no power
supply.
The thermal
Wait until the pump
protector
has cooled down. The
incorporated in the
thermal protector will
pump (if any) has
automatically reset.
tripped.
The thermal relay
Reset the thermal
or motor protector
protection.
in the electric
control panel has
tripped.
The protective
Check:
device against dry
running has
tripped.
The fuses for the
Replace the fuses.
pump or auxiliary
circuits are blown.
7.3 The pump unit starts, but the
thermal protector trips or the fuses
mains pressure.
Restore the
power supply.
Make sure all
electrical
connections to
the power supply
are intact.
liquid level in the
tank, or the mains
pressure.
protective device
and its
connecting
cables.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Lowara eshf atex

Table des Matières