Adam Equipment Eclipse EBL Série Notice D'utilisation page 29

Masquer les pouces Voir aussi pour Eclipse EBL Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

EN
Place the item on the pan. The animal weighing test will begin automatically.
After the pre-configured delay and test time have elapsed (see section 10.4.4.3 on
Dynamic Weighing Setup Parameters), the "
Remove the item from the pan. Press [Mode] to go back to "rUN
[
0/T] to return to normal weighing.
10.4.4.3
Animal (Dynamic) Weighing Setup Parameters
Animal
When the "
" symbol is displayed, and you have selected "SEtvP
for dynamic weighing (see section 10.4.4.3 on Dynamic Weighing Setup Parameters):
Press [Select] to select "SEtvP
The display will show "MODE
select "AvtO
AvtO" or "mmAnvAL
mAnvAL".
AvtO
AvtO
mAnvAL
mAnvAL
If "AvtO
AvtO" or "mmAnvAL
mAnvAL" is selected, the following 4 parameters are available:
AvtO
AvtO
mAnvAL
mAnvAL
• Threshold
• Mode
• Delay
• Test time
10.4.4.3.1
Threshold
Press [Select] when "THRESH
weight of the item required by the balance to start the process for dynamic weighing. The
value shown will be the current value in the last selected unit.
The minimum threshold value can be changed from 1.0 to 100 grams using the keypad
numeric entry method. If a value outside this range is selected then it will not be accepted
and "ER LOW
ER LOW" or "ER HIGH
ER HIGH" will be displayed followed by return to the weight entry screen
ER LOW
ER LOW
ER HIGH
ER HIGH
again.
To confirm the desired value, press [Select] or to escape without changing the value,
press [Mode].
10.4.4.3.2
Mode
Auto "AvtO
AvtO
AvtO
AvtO" or Manual "mmAnvAL
[Select] is pressed becomes the active mode. Auto starts dynamic weighing test as soon
as weight exceeding a set threshold is loaded on the pan. Manual requires the user to
load the pan and then press a button before weighing commences.
10.4.4.3.3
Delay
Press [Select] when "DELAY
seconds pause before the sampling starts. The Delay value can be changed to between 0-
99 seconds using the keypad numeric entry method. If a value outside this range is
© Adam Equipment Company 2015
SEtvP
SEtvP" to change the dynamic weighing mode settings.
SEtvP
MODE
MODE
MODE". Press [Select] again and use the [Up] or [Down] keys to
"THRESH
THRESH"
THRESH
THRESH
"mode
mode"
mode
mode
"DELAY
DELAY"
DELAY
DELAY
"TEST T
TEST T"
TEST T
TEST T
"THRESH
THRESH
THRESH" (For Auto mode only)
THRESH
THRESH" is shown and the display will next show the minimum
THRESH
THRESH
"mode
mode"
mode
mode
mAnvAL
mAnvAL
mAnvAL" modes are available. Whichever mode is visible when
"DELAY
DELAY"
DELAY
DELAY
DELAY" is shown and the display will next show the number of
DELAY
DELAY
HOLD
" symbol and the result will be displayed.
rUN" to weigh another item, or
rUN
rUN
SEtvP" to set up the balance
SEtvP
SEtvP
27
3016612482 Rev1-Aug15

Publicité

Chapitres

Table des Matières
loading

Table des Matières