SPECIFIC INSTRUCTIONS

ATTENTION!
The figures mentioned in the chapters are shown on the initial pages of this manual.
APPLIANCE DESCRIPTION
Robust steel frame, with 4 legs (adjustable in height(.
18/10 chrome-nickel steel outer panelling. The burners are
in brass, cast iron and aluminium.
The heating capacity may be adjusted from the maximum
EN
to the minimum through a gas safety valve.
The appliance is also fitted with a thermoelectric ignition
safety device (thermocouple(.
The grids are in enamelled cast iron.
The burners are in cast iron.
The cooking chamber is made in stainless steel.
The double-lined, heat insulated door has an insulated
handle and hinge with balanced spring.
The cooking chamber is insulated with glass wool.
Gas version
The burners are made to withstand thermomechanical
stress. The gas supply is controlled by a safety valve with
thermostat.
The main burner has a thermoelectric safety lighting
device (thermocouple(.
Oven temperature may be set anywhere between 160 °C
and 300 °C by a thermostat.
Electric version FE
The resistances are placed in the roof (top heat( and floor
(bottom heat(.
The temperature may be regulated between 50 °C and
270 °C by a thermostat connected to a three-pole switch.
The top and bottom resistances may be switched on
simultaneously or individually.
Electric (fan) version FE1 and FE2
The motor is located at the back of the oven at the centre
of the circular heating element. The temperature may be
regulated by a thermostat. Warning lights indicate when
the appliance is working and the power switched on.
The cooking chamber is in stainless steel. There is no flue-
gas collector in the cooker with an electric oven.
Very thick structure with central filler. (TP 40( stainless
burners and (TP80( cast iron burners. A safety gas cock
GAS HOB
OVEN
FULLPLATE
MOD.
N°:
Qn
V
kW:
Hz: 50/60
allows the heating capacity to be adjusted from maximum
to minimum. A pilot burner governs the ignition of the
main burners.
ASSEMBLY
Location
The appliance should be installed in a well ventilated
room, and if possible under a range hood.
The appliance can be installed on its own or alongsideother
equipment.
The installation of the models with a side terminal board
must be carried out while keeping the unit 15 cm from
the back wall and 50 cm from the side walls. In models
with a back terminal board or with back cable input, the
installation must be carried out while keeping the unit
50 cm from the back wall and 50 cm from the side walls.
In any case the unit must be installed/fixed in order it
is possible to replace the power supply cable after the
unit is installed. The walls near the appliance (walls,
decorations, kitchen cabinets, decorative finishes, etc.)
must be made of non-flammable material.
Before connecting up the appliance to the gas supply,
check on the data plate that the appliance is fitted for the
type of gas available.
If not, consult paragraph "Running the appliance on other
types of gas".
Legal and technical requisites
During assembly, the following legal and technical
requisites should be adhered to:
- relevant national legislation;
- local building and fire safety regulations;
- industrial injury legislation;
- local Gas Board regulations;
- current CEI regulations.
INSTALLATION
Assembly, installation and maintenance must all be done
by contractors authorised by the local Gas Board in
accordance with local and national legislation.
Before doing anything else, seek advice from your Gas
Board. The manufacturer declines all liabilities in the event
that the unit works incorrectly because of an incorrect
installation or because it does not comply with the
regulations in force.
Installation procedure
To level the appliance correctly, adjust the height of the
IPX2