8.

Connection Example

Example: Connection of 3-way valve
1 Electric T-junction
2 System line
3 Electronic module
4 Transformer 24 V AC
5 3-way valve
6 Power switch
7 Thermostat
8 Damp-room junction box with terminal block
Blind cap (not used)
Terminal of
junction box
1 ( )
2
3
9.

Assembly Instructions

9.1
Connect the power-switch plug to the correspondingly programmed actuator output
of the electronic module.
9.2
Connect the switching contact of the power switch according to its layout specifi-
cation shown on the label.
When the switching contact is active, the corresponding LED on the power switch
lights up.
9.3
Connect the surface temperature sensor to the piping to be measured (see MBA 18-
05.646a).
9.4
Connect the system-line connector of the electronic module to the coupling of the
electronic T-junction.
Terminal in
3-way-valve
3 (
)
1