Electrical Connection - Franke MYTHOS FMY 839 HI 2.0 Manuel D'utilisation

Masquer les pouces Voir aussi pour MYTHOS FMY 839 HI 2.0:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 43
surface, or drop hard objects
onto it.
Never drag pots and pans

ELECTRICAL CONNECTION

Electrical connections must
Z
X
be carried out by a trained
technician.
This appliance has a "Y" type
Z
X
connection, so the power cable
must have a "neutral" wire.
The power cable must be at
least of type H05VV-F. SINGLE
PHASE, TWO PHASE and THREE
PHASE connection: min. cross-
section of wires: 2.5 mm².
External diameter of the power
cable: min. 7 mm - max. 15 mm.
The connection terminals can
Z
X
be accessed by removing the
junction box cover.
Check that the domestic power
Z
X
supply characteristics (voltage,
maximum power and current)
are compatible with those of the
appliance.
Connect the appliance as shown
Z
X
in the diagram (in compliance
FMY 839 HI 2.0
across the vitreous ceramic
surface.
with reference standards in force
nationally for mains voltage).
It is recommended that you use
Z
X
the H05V2V2-F 5 x 2.5 mm²
power cable. When using the
H05V2V2-F 5 x 2.5 mm² power
cable, follow the instructions
provided here: for three phase
connection, separate the 2 wires
and remove the blue sheathing
from the grey wires.
– 9 –
EN

Publicité

Table des Matières
loading

Table des Matières