BFT LEO C Instructions D'installation page 28

Masquer les pouces Voir aussi pour LEO C:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 32
5) SAFETY DEVICES
Note: only use receiving safety devices with free changeover contact.
5.1) TESTED DEVICES Fig. F
5.2) CONNECTION OF 1 PAIR OF NON-TESTED PHOTOCELLS FIG. C
6) CALLING UP MENUS: FIG. 1
6.1) PARAMETERS MENU (PARA ) (PARAMETERS TABLE "A")
6.2) LOGIC MENU (LOGIC) (LOGIC TABLE "B")
6.3) DEFAULT MENU (default)
Restores the controller's DEFAULT factory settings. Following this reset, you will need
to run the AUTOSET function again.
6.4) LANGUAGE MENU (language)
Used to set the programmer's language on the display.
6.5) STATISTICS MENU
Used to view the version of the board, the total number of operations (in hundreds),
the number of transmitters memorized and the last 30 errors (the first 2 digits indicate
the position, the last 2 give the error code). Error 01 is the most recent.
6.6) PASSWORD MENU
Used to set a password for the board's wireless programming via the U-link network.
With "PROTECTION LEVEL" logic set to 1,2,3,4, the password is required to access the
programming menus. After 10 consecutive failed attempts to log in, you will need to
wait 3 minutes before trying again. During this time, whenever an attempt is made to
log in, the display will read "BLOC". The default password is 1234.
7) OPEN IN OTHER DIRECTION (Fig. B)
If the "op. d ir. r ev. * logic is on 1 the opening direction is reversed in comparison with the
standard operation and the limit switches are interpreted the opposite way.
28 -
LEO C
INSTALLATION MANUAL
8) CONNECTION WITH EXPANSION BOARDS AND UNIVERSAL HANDHELD
PROGRAMMER VERSION> V1.40 (Fig. B) Refer to specific manual.
9) RADIO-RECEIVER (Fig. B)
The board comes ready for connection of removable radio-receiver.
The receiver's channel 1 controls input IC1.
The receiver's channel 2 controls terminals 26-27.
10) U-LINK OPTIONAL MODULES
Refer to the U-link instructions for the modules.
The use of some models causes lowered radio capacity. Adjust the system using an
appropriate antenna tuned to 433MHxz.
11) Opposite sliding leaves (Fig. H)
Refer to the U-link instructions for the modules.
NOTE: On the board set as the Slave, the Safety Edge input (Safety Edge/ Test Safety
Edge/ 8k2 Safety Edge) should only be set to SAFE2.
12) RESTORING FACTORY SETTINGS (Fig.G)
WARNING: this operation will restore the control unit's factory settings and all transmit-
ters stored in its memory will be deleted.
WARNING! Incorrect settings can result in damage to property and injury to people
and animals.
- Cut off power to the board (Fig.G ref.1)
- Open the Stop input and press the - and OK keys together (Fig.G ref.2)
- Switch on the board's power (Fig.G ref.3)
- The display will read RST; confirm within 3 sec. by pressing the OK key (Fig.G ref.4)
- Wait for the procedure to finish (Fig.G ref.5)
- Procedure finished (Fig.G ref.6)
WARNING! Incorrect settings can result in damage to property and injury to
people and animals.
WARNING: Check that the force of impact measured at the points provided for
by standard EN 12445 is lower than the value laid down by standard EN 12453.

Publicité

Table des Matières
loading

Table des Matières