PROBLEM
Use this
FAN DOES NOT
OPERATE WHEN
problem
THE ON/OFF BUTTON
solver!
IS PUSHED
FAN KEEPS GOING
OFF AND ON
FAN FILTER LIGHT IS ON • After 30 hours of "on" or running time, the light reminds you to clean the
FAN DOES NOT OPERATE • The blower connector is loose or not plugged into its mating connector.
WHEN FAN ON/OFF
BUTTON IS PRESSED OR
WHEN + OR – BUTTON
IS PRESSED
LOUD OR ABNORMAL
AIRFLOW NOISE
FAN FAILS TO CIRCULATE • Obstructions in duct work. Make sure nothing is blocking the vent. Make
AIR OR MOVES AIR
SLOWER THAN NORMAL
AND/OR FAN IS MAKING
LOUD OR ABNORMAL
AIRFLOW NOISE
THE HOOD CONTROLS
ARE NOT OPERATING
CORRECTLY
EARLY BULB FAILURE
POSSIBLE CAUSE
• A fuse may be blown or a circuit breaker tripped. Replace fuse or
reset circuit breaker.
• The motor is probably overheating and turning itself off. This can
be harmful to the motor. Check to be sure the filter is clean. If off
and on cycling continues, call for service.
metal grease filters. The light will glow until the filters are replaced.
• The right-side filter is not making contact with the switch. Adjust the
filter in place.
Disconnect power to the unit. Lift the lower duct cover and look at the
blower connector plug. If the blower connector plug is loose, plug it in
securely. See the Installation Instructions for the plug location and how
to plug in the connector.
• Wrong size duct used in installation. This hood requires 6" ducting
and a maximum duct length of 100 equivalent feet to perform optimally.
Using smaller duct pipe or longer equivalent lengths of duct pipe will
cause improper venting. GE service technicians cannot correct this issue
if installed improperly.
sure your wall or roof cap has a blade or door.
• Damper blade on wall or roof cap may not be open. Make sure damper
swings freely. Damper blades may flip over and will not fully open when
this happens. Adjust to original position.
• Metal grease filter and charcoal filter (if present) may be dirty. Clean
the metal grease filter and replace charcoal filter (if present). See Care
and Cleaning.
• Control logic confused. Disconnect power to the hood by resetting
the circuit breaker. Wait 30 seconds to allow controls to reset.
• Replacing bulbs with bare hands. Replace bulbs while wearing gloves
to keep skin oils off bulbs.
• Bulb wattage is too high. Replace with correct wattage.