BEFORE USING THE WINDLASS READ THESE INSTRUCTIONS CAREFULLY.
IF IN DOUBT, CONTACT YOUR NEAREST "QUICK
WARNING: the Quick
Quick
shall not be held responsible for damage to equipment and/or personal injury, caused by a faulty use
®
of the equipment.
Always deactivate the windlass when not in use.
The splice between the rope and the chain must be tightly woven for the rope to slide easily into the gypsy shape. For any
problem or request, feel free to contact Quick
two anchor windlass controls in case one is accidentally damaged.
gnetic switch as the motor safety switch.
The contactor unit or reversing contactor unit must be installed in a point protected from accidental water contact.
After completing the anchorage, secure the chain or rope to fixed points such as chain stopper or bollard.
To prevent accidental releases, the anchor must be secured. The windlass shall not be used as the only securing device.
Isolate the windlass from the power system during navigation (switch the circuit breaker off) and lock the chain securing it to
a fixed point of the boat.
THE PACKAGE CONTAINS: windlass - reversing contactor unit - base gasket - drill template - handle - bolts and screws (for assem-
bly) - user's manual - conditions of warranty.
TOOLS REQUIRED FOR INSTALLATION: drill and drill bits: Ø 9 mm (23/64") and Ø 11 mm (7/16") - Ø 40 (1" 9/16) hollow mill; hexag-
onal wrenche: 13 mm.
"QUICK
"ACCESSORIES RECOMMENDED: anchoring RL control board (mod. 800) - Waterproof hand helds R/C (mod. HRC 1002) -
®
Foot switch (mod. 900) - Hydraulic-magnetic circuit breaker - Anchor chain counter (mod. CHC 1102M and CHC1202M) - Radio control
RRC (mod. R02, P02, H02).

INSTALLATION REQUIREMENTS:

upper and lower surfaces of the deck are as parallel as possible. If this is not the case, compensate the difference appropriately (a lack
of parallelism could result in a loss of motor power). The deck thickness must be included among the figures listed in the table. In cases
of other thicknesses it is necessary to consult a Quick
and chain; lack of depth of the peak could cause jamming.

FITTING PROCEDURE:

excess material from the chain through hole, ensuring the free passage of the chain or rope. Position the windlass lowering it from
above deck and inserting the gasket between the deck and the base. Screw the stud bolts, using the short threaded end, onto the base.
Apply a medium grade locking product onto the thread. Fix the windlass by screwing the nuts onto the fixing studs. Connect the supply
cables from the windlass to the reversing contactor unit.
WARNING: before wiring up, be sure the electrical cables are not live.
GP2 SERIES GENIUS 1500/2000 - REV000A
windlasses are designed to weigh the anchor.
®
The windlass is not designed for the loads that might occur in extreme weather conditions (storms).
®
Secure the chain with a further device before starting the navigation.
the windlass must be positioned with the gypsy aligned with the bow roller. Ensure that the
®
MAX 5 MM
(3/16")
when the ideal position has been established, drill four holes using the drilling template provided.Remove
45°
" DEALER.
®
Do not use the equipment for other purposes.
Check that there are no swimmers nearby before dropping anchor.
Technical Service.
For improved safety we recommend installing at least
We recommend the use of the Quick
retailer. There must be no obstacles under deck to the passage of cables, rope
40 CM
(16")
INSTALLATION
®