EcoFlex™ system disabling procedure
(For machine with EcoFlex™ system)
In order to temporarily disable the system, lift the EcoFlex™ lever (D, Fig. 4) and keep it lifted for 2 seconds.
After this procedure, (LED (D) off), the detergent concentration level is the one which has been set.
To enable the system, lift the EcoFlex™ lever (D) again.
In order to permanently disable the EcoFlex™ system, proceed as follows:
1.
Turn off the machine by turning the ignition key (58) to "0".
2.
Lift the lever (D), then turn the ignition key (58) to "I".
3.
Release the lever (D) at least 8 seconds after turning on the machine.
After this procedure, the EcoFlex™ lever cannot be operated again (LED (E) off) and the detergent concentration level is the one
which has been set.
In order to re-enable the system, repeat the steps 1 to 3.
NOTE
The permanent disabling of the EcoFlex™ system is stored into memory even after the machine is turned off.