fully installed according to the instructions.
Decide where to install the electric
radiator. Make sure there is enough free
space for the circulation of air round the
eelectric radiator and that there is no
flammable material nearby. Do not place
the electric radiator behind a door. The
bottom edge of the electric radiator must
be at least 30 cm above the floor, the
sides at least 30 cm from adjacent walls,
and the top edge at least 150 cm from the
lowest part of the ceiling.
FIG. 3
INSTALLATION
Fit the two brackets on the wall. Fit the
left and right bracket turned towards each
other, with the slot upwards and the short
part to the wall. Drill two holes in the wall
at the same height, at last 610 mm above
the floor and 255 mm apart.
A
B
C
FIG. 4
Put screw plugs in the holes and screw the
brackets to the wall with two large screws.
Fit the other two brackets with two
smaller screws on the underside of the
electric radiator. Fit the brackets by
screwing through the long part, with the
short part facing down. The short part will
rest on the wall.
FIG. 5
Hang up the electric radiator on the wall
brackets and check that it drops into the
slots.
The short part of the two bottom brackets
will rest on the wall. Mark out where on
the wall they are to be mounted and lift
off the electric radiator.
255 mm
485 mm
305 mm
Description for diagram 6
1.
Screwdriver
2.
Screw
3.
Screw plug
4.
Hole
FIG. 6
Drill two holes at the markings and insert
the screw plugs.
Put the electric radiator on the brackets
again and check that it drops into the
slots. Screw the bottom brackets to the
wall with two large screws.
FIG. 7
FIG. 8
Check that the electric radiator is level and
positioned at the minimum specified
distance from the wall, ceiling and floor.
USE
PREPARATIONS AND USE
Check that the power switch is switched
off (O).
Check that the electric radiator is firmly
mounted and level on the wall according
to the instructions.
Plug the plug into a power point.
Put the power switch in the ON position
(I). The display shows OFF.
NOTE:
After a power failure, the radiator must be
restarted and any settings made again.

USING THE CONTROL PANEL

There are 6 buttons on the control panel:
1.
MOD
2.
SET
3.
WEEK
4.
(+) increase set value
5.
(-) reduce set value