A backflow prevention device must be installed be-
tween the drinking water and the high-pressure
cleaner! Ask your plumbing expert about this.
Suction from open tanks/containers and natural
bodies of water
Use a special self-suction accessory (not included
with delivery / available from dealer).
With this accessory, the high-pressure cleaner can
take in water 0.5 m above the water level. This can
last about 25 to 50 seconds.
Immerse the accessory's hose completely under wa-
ter to drive the air out of the hose.
Connect the accessory's hose to the high-pressure
cleaner, and make sure that the suction strainer re-
mains under water.
Let the high-pressure cleaner run with the spray gun
removed until the water flows evenly out of the high-
pressure hose.
If no water comes out after 25 to 50 seconds, switch
off and check all connections.
Once the water is flowing, turn off the high-pressure
cleaner and connect the spray gun and spray lance
to start work.
High-pressure hose connection (fig. 3/4)
Connect the high-pressure hose (5) to the connec-
tion for the high-pressure hose (6). Remove the pro-
tective cover first.
Insert the other end of the high-pressure hose (5)
into the pistol connection (12).
To remove the high-pressure hose (3), press the but-
ton Taste (A) and pull it out.
Connecting the attachments (fig. 5)
To mount attachments 13, 15 press them into the
pistol (12) and turn them until the lock.
To fit the nozzle (14), insert it in the extension (13)
and turn until it locks.
20 | GB
 www.scheppach.com /  service@scheppach.com /  +(49)-08223-4002-99 /  +(49)-08223-4002-58

9. Operation

The equipment consists of an assembly with a pump,
which is encased in a shock absorbing housing. The
equipment comes with a lance and a non-slip gun (for
an optimal working position), whose shape and con-
figuration comply with the applicable regulations.
Commissioning:
Once you have completely assembled the high-pres-
sure cleaner and all connections have been made,
proceed as follows:
Turn on the water supply. Unlock the pistol (12) via
the locking switch (C). Pull back the trigger lever (D)
so that the air in the device can discharge. (Fig. 4)
Switch on the device by setting the on/off switch (4)
to "ON". Next, press the trigger lever (D). (Fig. 1/4)
To switch off, release the trigger lever (D), and the
device switches to stand-by. The high-pressure
cleaner starts again when you press the trigger le-
ver (D). (Fig. 4)
To switch off the high-pressure cleaner completely,
set the on/off switch (4) to "OFF". (Fig. 1)
Cleaner container (10)
Fill the cleaner container with the corresponding
cleaner.
Spraying cleaning agents
Cleaning agent is dosed in a low-pressure process.
The nozzle (14) must be disassembled for this.
Using the attachments (fig. 1):
Nozzle (14): For coarse cleaning work.
STERWINS adapter (15): Use this adapter to attach
STERWINS brand accessories.
Transport (Fig.1)
Pull the pull-out handle (1) upwards and tilt the high-
pressure cleaner on the transport wheels (9).
Storage
Store the accessories as shown in Fig. 1.