Basic Troubleshooting - Wacker Neuson HI400HD D Notice D'emploi

Masquer les pouces Voir aussi pour HI400HD D:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Basic Troubleshooting

8
Basic Troubleshooting
8.1
Basic Troubleshooting
Problem
The burner does not start
The burner starts, the flame
does not ignite, the unit
locks out
The burner starts, flame
ignites, but the unit locks
out
The burner ignites but the
performance is poor
Black smoke from vent pipe
The machine stops due to
pressure switch fault
Cause
The remote thermostat or
thermostat plug is not
inserted correctly.
Faulty cable or power
supply
The over temperature
limit has tripped
The burner is in lock-out
mode.
No fuel
Worn burner nozzle
Faulty electrodes
Cad cell detecting
external light.
Cad cell defective
Burner control defective
Incorrect fuel pressure
Worn burner nozzle
Incorrect air lock setting
Cad cell defective
Burner control defective
Worn burner nozzle
Clogged fuel filter
Air leaks in the fuel lines
Insufficient oil pressure
Insufficient combustion air
Insufficient ventilation air
Overheat condition
Faulty pressure switch
Incorrect nozzle
Wrong fuel pressure
78
HI400HD D / HD G
Remedy
Insert the remote
thermostat or thermostat
plug.
Check cable and power
supply
Press the reset button.
Fill fuel tank
Replace burner nozzle
Replace electrodes
Check the Cad cell
enclosure
Increase fuel pressure
Replace burner nozzle
Re-adjust air lock setting
Replace burner nozzle
Replace the fuel filter
Inspect the lines for leaks;
replace if necessary
Remove any obstructions
from the air inlet and outlet
areas.
Contact Wacker Neuson
Product Support
ghi_tx001466gb_FM10.fm

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Hi400hd g

Table des Matières