Machine Description And Intended Use - Wacker Neuson HI400HD D Notice D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Safety Information
1.2

Machine Description and Intended Use

Machine
The HI Heater is an indirect-fired air heater. Depending on the model, the machine
description
operates either on diesel fuel (oil) or natural gas / Liquid Propane (LP). The
machine consists of the following components:
■ Stainless steel combustion chamber and heat exchanger
■ Blower
■ Two-stage burner (oil model)
■ High-temperature shut-down device
■ Fuel tank (oil model)
■ Gas selector valve (gas model)
■ High and low voltage control (gas model)
Fuel is consumed in a closed combustion chamber. Room air or outside air
(depending on the application) is pulled into the machine where it is heated. This
clean, dry, hot air is then blown by the blower into the space to be heated . Access
to the blower assembly is protected by a guard fitted on the air inlet.
Intended use
The HI Heater is intended to provide heat on outdoor or indoor construction sites (if
properly vented) and in other rugged applications.
This machine has been designed and built strictly for the intended use described
above. Using the machine for any other purpose could permanently damage the
machine or seriously injure the operator or other persons on the work site. Machine
damage caused by misuse is not covered under warranty.
Do not use this machine indoors without proper exhaust venting designed for
indoor use which meets all applicable regulations.
This machine has been designed and built in accordance with the latest global
safety standards. It has been carefully engineered to eliminate hazards as far as
practicable and to increase operator safety through protective guards and labeling.
However, some risks may remain even after protective measures have been taken.
They are called residual risks. On this machine, they may include exposure to:
■ exhaust emissions
■ hot surfaces such as exhaust vents and fuel heater
■ fuel and fuel fumes when refueling
■ high voltages and arc flash
To protect yourself and others, make sure you thoroughly read and understand the
safety information presented in this manual before operating the machine.
Optional
Wacker Neuson Corporation offers many optional accessories for the machine.
accessories
These accessories include the following:
■ Remote thermostat
■ Duct adapters (various sizes, available as kits, or individual ducts at 25 ft.
lengths).
■ Exhaust vents and elbows
Contact your Wacker Neuson dealer for more information.
12
HI400HD D/ HD G
ghi_si000468gb_FM10.fm

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Hi400hd g

Table des Matières