Installing The Remote Thermostat Or Receptacle Cap - Wacker Neuson HI400HD D Notice D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Operation
4.20

Installing the Remote Thermostat or Receptacle Cap

■ Remote thermostat, or
Requirements
■ Thermostat receptacle cap
Background
The control panel includes a receptacle for an optional remote thermostat (b). The
receptacle is protected by an attached cap (a) when not in use.
NOTICE: To avoid damaging or contaminating the receptacle, make sure the cover
is securely locked in place when a remote thermostat is not installed.
To install the remote thermostat, remove the cap, insert the plug into the
receptacle, and lock the plug in place.
■ When the mode switch is set to the upper (continuous heat) position, the heater
Operational
notes
will operate without a remote thermostat.
■ When the mode switch is set to the lower (remote thermostat) position, the
heater will not operate unless a remote thermostat is plugged into the receptacle
and the signal is read by the controller.
Thermostat
An adapter is available to convert the proprietary thermostat connection to an
adapter
Edison plug-style connection for use with commonly available thermostats. This
adapter can be purchased using Wacker Neuson part #5200007098.
NOTICE: The thermostat adapter is designed for use ONLY with a thermostat. To
avoid damaging the machine, do not plug any other equipment into the thermostat
adapter.