HI400HD D / HD G
4.18

Flex Ducting Options

Refer to the chart below for the maximum allowable return and supply duct lengths
for your machine.
NOTICE: Do not exceed the maximum total lengths specified in the chart.
Exceeding these lengths, or blocking any of the duct openings, constricts the air
flow through the machine and may cause a high-temperature shut-down fault.
MODEL
Supply
Duct
Adapter
AB XHD
1 x 20 in.
HI770
1 x 16 in.
2 x 12 in.
HI110
12 in.
HI200
14 in.
HI300
3 x 16 in.
HI300
4 x 12 in.
HD
HI400
1 x 20 in.
D/G
2 x 16 in.
3 x 12 in.
HI750
2 x 20 in.
HI900
3 x 20 in.
HI1000
3 x 16 in.
4 x 12 in.
HIF690
1 x 20 in.
HIF600
1 x 20 in.
1 x 16 in.
2 x 12 in.
HIF1200
2 x 20 in.
2 x 16 in.
4 x 12 in.
ghi_tx001462gb_FM10.fm
SUPPLY DUCTING
Length
of each
Maximum duct
duct
sections per
section
opening
(ft)
Qty
Length
25
8
200 ft
25
6
150 ft
25
3
75 ft
25
1
25 ft
25
1
25 ft
25
1
25 ft
25
2
25 ft
25
4
100 ft
25
2
50 ft
25
1
25 ft
25
6
150 ft
25
9
225 ft
25
3
75 ft
25
1
25 ft
25
4
100 ft
150
6
150
100
4
100
100
4
200
25
8
15 ft
25
2
50 ft
25
1
25 ft
RETURN DUCTING
Total
Return
combined
Duct
length
Adapter
200 ft
1 x 20 in.
150 ft
150 ft
25 ft
Return ductwork not available.
25 ft
25 ft
50 ft
100 ft
1 x 20 in.
100 ft
75 ft
300 ft
2 x 20 in.
675 ft
225 ft
100 ft
100 ft
1 x 20 in.
150
1 x 20 in.
100
200
300 ft
1 x 20 in.
100 ft
100 ft
43
Operation
Maximum
Total
number of
combined
25 ft duct
length
secitons
8
200 ft
4
100 ft
4
100 ft
4
100 ft
1
25 ft
4
100 ft

Publicité