High And Low Voltage Protection (G Models) - Wacker Neuson HI400HD D Notice D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Operation
4.26

High and Low Voltage Protection (G Models)

Serial Number
20105810 and higher
Range
Introduction
Your machine is equipped with a control board that offers high and low voltage
protection. This enhanced control board controls burner operation when the
voltage drops or spikes for prolonged periods. If you wish to install this enhanced
control board on a machine outside the serial number range listed above, contact
Wacker Neuson.
Operation
During high and low voltage conditions, machines equipped with this feature
operate as shown in the table below.
If the Voltage:
Drops below 90 VAC
Rises above 90 VAC
Rises above 147 VAC
Drops below 147 VAC
Note: The machine can not be reset while the operating status indicator is blinking
orange.
Overriding
To override the 2 minute delay for restarting the machine after the voltage rises
restart delay
above 90 VAC, remove the plug from the power receptacle and immediately plug it
back in. If the problem persists, contact Wacker Neuson.
Duration
Action
10 seconds
Shuts down machine and initiates a
blinking orange operating status indicator.
2 minutes
Restarts machine.
Shuts down machine immediately.
Restarts the machine immediately.