HI400HD D / HD G
4.29
Operating at High Elevations (D models)
Background
If using the machine at or above elevations of 1524 m (5000 ft) asl (above sea
level), a high elevation kit, periodic monitoring, and additional maintenance are
necessary to preserve the machine's systems. The following procedures will
ensure that the machine runs smoothly and that premature soot build-up will be
reduced.
Guidelines
Use the guidelines below to ensure efficient operation of the machine. Refer to the
specific topic for details.
Task
1. Install a high elevation kit.
Item number 5200008502
2. Adjust the air damper.
3. Replace the burner nozzle.
4. Conduct a combustion analysis and
smoke spot test.
WARNING
Fire hazard. The use of incorrect nozzles could cause fire or impaired combustion.
Impaired combustion may cause under-firing, over-firing, sooting, sudden expulsion
of hot gases, and smoke.
► Use only the factory-installed or recommended nozzles.
ghi_tx001462gb_FM10.fm
When
Before operation
Before operation
Before operation
After installing the kit and
making any adjustments
and/or
Every 1000 hours
55
Operation
See Topic
—
6.7
6.6
6.3