5. Cleaning, Care and Maintenance

5.1 quarium
• Remove other visible waste and dead plant parts (EHEIM plant forceps).
• Every 3 to 4 weeks (depending on the stocking too often) perform partial water changes: exchange about 1/3 of water against
appropriately-tempered water; it immediately cleans the floor bottom (substrate cleaning kit); after changing the water, add
water treatment agents.
Occasionally (if necessary) clean panes, eliminate algae and chalk residues (with sponge, Screen wash). Clean floor with EHEIM
sludge cleaner. Control water quality.
• Clean the filter only, if the water flow is noticeably reduced.
5.2 Interior filter
G
Disconnect the mains plug. Remove the filter canister by pulling upwards. By exerting with your finger a little pressure
on the top of the motor housing, you will prevent the suction cups from slipping. The complete motor housing remains
in the aquarium and does not have to be removed.
H
Open the filter cover. Remove the cartridge and rinse lightly under lukewarm flowing water or replace (order no. for
2008: 2617080). The cart ridge can be used 2-3 times.
ttention: Never carry out water change and cleaning of the cartridge at the same time.
I
The impeller should not be removed for cleaning. Vigorously rinse the canister and impeller and ensure free movement
of the im peller.
Install the cleaned cartridge back into place, close filter cover and insert the complete canister back into the motor
hous ing.
5.3 Cover qua Star 54 switching of the fluorescent tube
A change of the fluorescent tube (15 Watt, 438mm Long) is recommended every 2-3 years.
Disassembly/ ssembly:
1. Pull power plug
2. Loosen fitting ring (Fig.1)
3. Push fitting ring over the pipes (Fig. 2)
4. Pull out the pipes without rotating forwards (Fig. 3).
The assembly is done in a reverse sequence. Note the correct positions of the pipes during the assembly and lightly lock the
fitting ring evenly by hand.
Change the starter:
Use only the starter, as per the Norm EN 60155. Screw cover of the Starter loose and insert new, suitable starter, then tighten
screw cap.
Guarantee
We provide the warranty on your aquarium lamp for the set Aqua Star 54 up to 24 months from date of purchase. The guarantee
covers all possible defects on integrated electronic parts (excl. fluorescent tubes). We provide the warranty on the aquarium
lamp for the set Aqua Star 54 LED up to 36 months from date of purchase. Damage due to intervention by the user is not co-
vered.
We provide the warranty on the aquarium, Inner filter heater controls up to 36 months from date of purchase, excluding glass
panes and manhandling. No liability is accepted for fish, plants and consequential damage in your flat – even during the guarantee
period. Please do not remove the label on the bottom of the base plate as otherwise the warranty claim will no longer apply.
Within the guarantee period our repairs are free of charge.
For recognition of the guarantee a dated purchase receipt, as well as compliance with the operating instructions is essentially