MADE IN FRANCE

CONTROLS AND MAINTENANCE

Inspections and maintenance work are carried out by authorised personnel at the specified maintenance intervals. Do
not use water or flammable liquids for cleaning. The following points must be observed to ensure a long service life and
proper use of the pneumatic jack:
- Only original spare parts may be used «Spare parts (page 12)».
- The recommended maintenance intervals must be observed «Maintenance table (page 8)»
- For maintenance work that is not covered or indicated in the operating instructions, contact your dealer and/or the
GYS after-sales service.
Clean the jack at least once a week to remove all dust and dirt that could degrade the proper
i
functioning of the product in the long term. Use self-cleaning cloths. Do not use any water nor
flammable or corrosive liquids.
Only carry out maintenance work when the jack is raised and held on its 2 unloaded supports while
removing the air hose.

MAINTENANCE TABLE

Maintenance
intervals
Monthly
Annual
Every 5 years of
service
Properties and life span of bellows:
Bellows are flexible elements made of an ageing rubber casing. They must be checked particularly carefully.
Advice for a long life:
- Use dry, non-lubricated compressed air.
- Protect the bellows from UV radiation (e. g. from welding or UV drying).
- Avoid the use of chemicals.
- Protect the bellows from mechanical damage (perforations, etc.).
- Observe the maintenance and care instructions «see chapter Lubrication points (page 9)».
It is imperative to replace damaged or cracked bellows. Only original manufacturer's parts are allowed.
16
Task
Check, clean and lubricate all moving parts, including
the axes and sliding surfaces of the scissors.
Check the condition of the rubber pads and clean them.
Check the bellows and pneumatic hoses for damage.
Visual inspection and waterproofing control. Check the
surfaces of the bellows for impurities, clean and treat it.
Check the function and tightness of the pressure relief
valve.
Check the fixing of the plastic clamps and the
beam fasteners on chisel and platters.
«Regular safety check (page 14)»
Replace the complete set of pneumatic hoses.
SPOT LIFT PRO
Refer to «Check and Lubrication Point (page 9)».
Remove if necessary.
Refer to «Bellows Properties and Lifetime (page
9)».
Without load, with an inlet pressure of between 6
and 7 bar, lift the jack up to the maximum until you
hear the exhaust noise of the valve..
Replace plastic clamps if necessary.
For the test protocol, refer to «Regular safety
check (page 14)».