7. Starting, operation
Specifications
Model D-20-9, D-21-9
Adjustability zero/span
%
Response time (10 ... 90 %)
ms
Internal measuring rate
Hz
Accuracy
% of span
4)
Accuracy 0.3%
5)
Including non-linearity, hysteresis, zero point and full scale error (corresponds to
error of measurement per IEC 61298-2).
Adjusted in vertical mounting position with lower pressure connection.
Non-linearity
% of span
Non-repeatability
% of span
1-year stability
% of span
Permissible temperature of
Medium
6) *)
Ambience
6)
Storage
6)
Also complies with EN 50178, Tab. 7, Operation (C) 4K4H, Storage (D) 1K4,
6)
Transport (E) 2K3
Compensated temp range
Temperature coefficients within
compensated temp range
Mean TC of zero
% of span
Mean TC of range
% of span
CE- conformitiy
Pressure equipment directive
EMC directive
Shock resistance
g
Vibration resistance
g
10
WIKA Operating instructions/Betriebsanleitung/Mode d'emploi/Instrucciones de servicio D-2X-9
+/- 10 by entries into object directory
1.5 (Baud rate ≥ 125 K)
1000 (adjustable to approx. 4 Hz)
≤ 0.5
{0.25 or 0.15}
4)
(BFSL)
≤ 1
5)
{0.5 or 0.3}
4) 5)
5)
or 0.15% (BFSL) is not available in combination with DIP-switch.
≤ 0.2
(BFSL) according to IEC 61298-2
≤ 0.1
≤ 0.2
(at reference conditions)
-30 ... +100 °C {-40 ... +125 °C}
-22 ... +212 °F {-40 ... +257 °F}
-20 ... +80 °C
-4 ... +176 °F
-40 ... +100 °C
-40 ... +212 °F
0 ... +80 °C
32 ... +176 °F
≤ 0.2 / 10 K
≤ 0.2 / 10 K
97/23/EC
89/336/EEC emission (class B) and immunity according to EN 61 326
500 according to IEC 60068-2-27
(mechanical shock)
20
7)
according to IEC 60068-2-6
(vibration under resonance)
GB
7. Starting, operation
Specifications
Wiring protection
Reverse polarity protection
Weight
*)
In an oxygen version model D-21-9 is not available. In an oxygen version model D-20-9 is only available with media temperatures
between -4 ... +140 °F / -20 ... +60 °C and using stainless steel or Elgiloy
{ } Items in curved brackets are optional extras for additional price.
When designing your plant, take into account that the stated values (e.g.burst pressure,
over pressure safety) apply depending on the material, thread and sealing element used.

Functional test

The output signal must be proportional to the pressure. If not, this might point to a
damage of the diaphragm. In that case refer to chapter 9 „Troubleshooting".
Open pressure connections only after the system is without pressure!
Observe the ambient and working conditions outlined in section 7 „Technical
data".
Warning
Please make sure that the pressure transmitter is only used within the over-
load threshold limit at all times!
When touching the pressure transmitter, keep in mind that the surfaces of
the instrument components might get hot during operation.
Caution
WIKA Operating instructions/Betriebsanleitung/Mode d'emploi/Instrucciones de servicio D-2X-9
Model D-20-9, D-21-9
7)
Only with option DIP switch, otherwise 10 g.
UB+ against UB-
Approx. 0.2
kg
Approx. 0.3 option with integrated Y-piece
®
wetted parts.
GB
11