Photocell; Eye- Cell Pre-Flash Setup - Elinchrom Ranger Quadra AS Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Photocell – Basic Functions
Press 1x
Scroll to select function
Photocell / Eye-Cell Setup - Anti-Red-Eye Pre-Flash Learning Mode
Press 1x
Press 1x
Special Photocell – Eye-Cell Setup (manual pre-flash configuration)
Change only if Photocell cannot identify camera pre-flashes. Advanced users only!
Photocell / Eye-Cell - Pre-Flash Time Frame Setting - Advanced users only!
Press 1x
Press 2x
Photocell / Eye-Cell - Pre-Flash Block Time Setting - Advanced users only!
Press 1x
Press 3x
Scroll to select
function
Scroll to
change value
Scroll to
change value
Photozelle OFF
Photozelle ON
Photocell Pre-Flash Mode (shows the
number of received camera flashes when
the camera on flash is set to Anti-Red-Eye
mode) To change values, please follow
instructions below.
Automatic pre-flash setup, Learning Mode.
Make a test exposure and release camera
flashes with activated Anti-Red-Eye function
The Ranger Quadra Photocell will recognize
all flashes and stores this value. The Pre-
Flash function is now active
Photocell / Eye-Cell setup, Preset Mode
ct. is the time window of all released anti
red-eye flashes incl. the main flash. Change
setting only when the pre-flash procedure is
longer than the manufacturer settings.
Set the value ct. between 1 and 7 to ensure
that all pre-flashes including the main flash
are inside the time frame
Standard value = 4
Pre-Flash Block -Time:
to set the minimum delay between each
pre-flash. (Normally only for LED Anti-Red-
Eye cameras) Standard value = 1
EN
12

Publicité

Table des Matières
loading

Table des Matières