Télécharger Imprimer la page

Novy Panorama 120 Pro Instructions D'installation page 23

Masquer les pouces Voir aussi pour Panorama 120 Pro:

Publicité

EN
POWER LIMITATION INDUCTION HOB
Power limitation induction hob
The hob is equipped with a power limitation. If the
power level on two zones exceeds the maximum power,
the last selected cooking zone will be maintained, and
the other cooking zone will be automatically reduced.
The display of this zone will flash first, then the level
is automatically reduced to the highest appropriate
position.
This restriction is set at the factory to 7400W (32A) on
the 4 zones hob reference 42110 and on 10400W (48A)
for the 5 zones hob reference 42120.
This power limit can be adjusted if required.
Configuration procedure:
• Make sure there is no more pot on the hob
• Disconnect the appliance from the grid by removing
the fuse or turning the circuit breaker off.
• Reconnect the table to the grid
• Start the procedure within 2 minutes after
reconnecting the hob to the grid
• Make sure all cooking zones are off.
• Do not press on
.
1)
Press the
2)
Each display shows a .
3)
With one finger of the other hand press suc-
cessively and quickly (in less than 2s) on the
. Starting from the front right area and turning
counter-clockwise
(1 -> 2 -> 3 (only 42120) -> 4 -> 5) then release
the
key. A double "beep" indicates an op-
erating error. In this case, repeat the operation
from step 1.
4)
Select the [
5)
Use the slider to make [
"4".
6)
Select the [
slider to enter the desired configuration in the
display :
Config.
0 corresponds to
1 corresponds to
2 corresponds to
3 corresponds to
4 corresponds to
5 corresponds to
6 corresponds to
7 corresponds to
8 corresponds to
9 corresponds to
* Note: in this configuration, the right and
middle zones are connected to the same
phase.
7)
Press the
configuration.
Never place container on the cooking zones
during setup.
23
key and hold it down.
C/0
] key in display "4".
C/8
] appear in display
0
] key in display "5" and use the
42110
42120
4 zones
5 zones
7400W - 2 fasen 10400W - 3 fasen
7400W - 2 fasen*
6900W - 3 fasen
5750W - 1 fase
5750W - 1 fase
4600W - 2 fasen 4600W - 2 fasen*
3700W - 1 fase
3700W - 1 fase
3000W - 1 fase
3000W - 1 fase
2750W - 1 fase
2750W - 1 fase
2300W - 1 fase
2300W - 1 fase
1400W - 1 fase
1400W - 1 fase
key for 2 seconds to confirm the