Attachment Of The Elements; Electrical Connections - Erreka ABC2M-009 Manuel De L'installateur

Cadre de manoeuvre pour l'actionneur "bul"
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

ABC2M-009_ES_FR_EN_PT_DE.book Page 45 Thursday, April 17, 2008 9:43 AM
3

ATTACHMENT OF THE ELEMENTS

1 Choose a location for the control panel, taking as a
reference the figure shown in "Elements of the
complete installation" on page 39.
The height from the ground must be
sufficient as to be out of the reach of children.
The attachment surface must resist the
weight of the control panel.
2 Make four holes and attach the control panel with
appropriate screws.
4

ELECTRICAL CONNECTIONS

Complete the installation in line with the low voltage regulations and applicable rules.
Use cables with sufficient section, and always earthed.
Check the manufacturer's instructions for all the elements installed.
Connection of the safety devices (photocells)
3 Attach the other elements of the installation in line
with the corresponding instructions.
4 Position the ducts for the cable, securing them firmly
using appropriate means.
In case of using push button for operating the
installation, it is recommendable to install
them
away
from
children´s
recommended heigh 1.6m).
Check the photocell instructions to carry out the
connections with the control panel.
We recommend installing interior and exterior
safety devices. If only one is installed, install the
exterior one.
Shown below is an example of the connections of a
KLPMUTO photocell as an exterior safety device.
1 Connect the NC contacts of the exterior device (1) in
the connector corresponding to the control panel.
Correctly programme the microswitches DIP1 and
DIP2 (see the photocell instructions).
2 The 24Vac connector can be used to power the
photocell.
3 When not using an exterior device, it is necessary to
make a bridge between the corresponding terminals
to the NC contacts of the exterior device.
4 If an interior safety device is not used, make a bridge
(2) in the corresponding connector of the control
panel.
When using an interior device, connect the NC
contacts of the device in the corresponding terminals
of the control panel.