Dry Vacuuming - Bosch GAS 55 M AFC Professional Notice Originale

Aspirateur eau et poussière
Masquer les pouces Voir aussi pour GAS 55 M AFC Professional:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 25
OBJ_BUCH-1747-001.book Page 22 Friday, February 15, 2013 8:02 AM
22 | English
To save energy, only switch the vacuum cleaner on when us-
ing it.
To ensure optimal vacuuming performance, always complete-
ly unwind the vacuum hose 27 from the vacuum cleaner lid
13.

Dry Vacuuming

Vacuuming of deposited dusts
– Set the airflow regulator 6 to the hose diameter being
used.
– To switch the vacuum cleaner on, set the mode
selector switch 7 to the "vacuuming" symbol.
– To switch the vacuum cleaner off, set the mode
selector switch 7 to the "Off" symbol.
The vacuum cleaner is equipped with an airflow monitoring
system. In the "vacuuming" operating mode, the airflow is
continuously set to a value of 20 m/s, independent of the po-
sition of the airflow regulator 6.
If this value is fallen below, e. g. caused through debris accu-
mulated in the vacuum hose, a full dust bag or a clogged flat-
fold filter, an alarm sounds. In this case, shut the vacuum
cleaner off and check it as described under "Correction of
Malfunctions".
Extraction of dusts resulting from running power tools
(see figure G)
 An adequate ventilation rate (L) must be provided for
when the outgoing air is circulated. Observe the re-
spective national regulations.
A socket outlet with earthing contact 5 is integrated in the
vacuum cleaner. An external power tool can be connected
there. Observe the maximal allowable load of the connected
power tool.
To ensure sufficient dust transport at the vacuum location,
the minimum airflow for the power tool connected must not
be fallen below.
Hose Diameter
35 mm
22 mm
15 mm
– Set the airflow regulator 6 to the hose diameter being
used.
– Mount the tool sleeve 25 (see "Mounting the Tool Sleeve",
page 21).
– Insert the tool sleeve 25 into the vacuum connection of the
power tool.
– To start the vacuum cleaner's automatic
Start/Stop feature, set the mode selector
switch 7 to the "Automatic Start/Stop" sym-
bol.
In this operating mode, the airflow is electronically moni-
tored according to the setting of the airflow regulator 6.
Sufficient dust transport is ensured when the setting is
correctly selected.
1 619 929 L62 | (15.2.13)
– To start the operation of the vac, switch on the power tool
connected to the socket 5. The vacuum cleaner starts au-
tomatically.
– Switch the power tool off to end the vacuuming.
The after-run function of the automatic Start/Stop feature
lasts approx. 15 seconds, so that residual dust is drawn
out of the vacuum hose.
– To switch the vacuum cleaner off, set the mode
selector switch 7 to the "Off" symbol.
When the alarm sounds, the vacuum cleaner must be checked
as described under "Correction of Malfunctions".
Wet Vacuuming (see figure H)
 Do not vacuum inflammable or explosive fluids; for ex-
ample, benzene, oil, alcohol, solvents. Do not vacuum
hot or burning dust. Do not operate the machine in
rooms where the danger of an explosion exists. The
dusts, vapours or fluids can ignite or explode.
 The vacuum cleaner may not be used as a water pump.
The vacuum cleaner is intended for vacuuming air and wa-
ter mixtures.
 Before any work on the vacuum cleaner itself, pull the
mains plug.
Note: The requirements for the ingress degree (dust category
M) have only been proven for dry vacuuming.
– Remove the disposal bag 29 or the dust bag and empty the
container 1 before wet vacuuming.
Note: For easier disposal when vacuuming liquid-solid mix-
tures, use a wet filter bag (accessory), which separates liq-
uids from solids.
– Mount the rubber lips into the floor nozzle (see "Inserting
the Rubber Lip", page 21).
– Switch the automatic filter cleaning (AFC) off (see "Deacti-
vating the AFC", page 23).
The vacuum cleaner is equipped with filling-level sensors 40.
When the maximum filling height is reached, the vacuum
cleaner switches off. Set the mode selector switch 7 to the
"off" symbol.
Airflow Setting Value
3
Note: When vacuuming non-conductive liquids (e. g. drilling
57.9 m
/h
emulsion, oil and grease), the vacuum cleaner is not switched
3
41.2 m
/h
off when the container is full. The level must be monitored
3
12.7 m
/h
continuously and the container emptied in time.
When the alarm sounds while wet vacuuming, the operational
safety of the VAC is not impaired. No measures are required to
correct the malfunction.
– Pull the drain hose 23 from its holder and drain the dirty
water via the drain hose.
– For transport of the vacuum cleaner, screw the plug cap 2
onto the hose connection piece 3.
To prevent the formation of mould after wet vacuuming:
– Take out the flat-fold filter 30 and allow it to dry well.
– Remove the vacuum cleaner lid 13 open the filter cover 39
and allow both components to dry thoroughly.
Bosch Power Tools

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

0.601.9c3.300

Table des Matières