Filter Cleaning

Automatic filter cleaning (see figure I)
In automatic filter cleaning mode (AFC = Automatic Filter
Cleaning), the flat-fold filter 30 is cleaned every 15 seconds
by means of air blasts (pulsating noise).
The filter cleaning system must be actuated latest when the
vacuuming performance is no longer sufficient.
Regular use of the filter cleaning feature increases the tool life
of the filter.
To achieve ideal filter tool life, deactivate the automatic filter
cleaning in exceptional cases, e. g., when vacuuming pure liq-
uids or when working with a paper filter bag.
A flat-fold filter contaminated only on the surface is fully func-
tional. Manual cleaning of the flat-fold filter by striking/tap-
ping against it or blowing it out is not necessary, and can even
damage the filter.
Note: The automatic filter cleaning is factory-set.
Switching the automatic filter cleaning on/off is only possible,
when the VAC is running.
– Deactivating the AFC
Actuate the AFC button 9.
The signalling LED 38 goes out.
– Activating the AFC
Actuate the AFC button 9.
The signalling LED 38 lights up green.

Maintenance and Service

Maintenance and Cleaning

 Before any work on the vacuum cleaner itself, pull the
mains plug.
 For safe and proper working, always keep the vacuum
cleaner and ventilation slots clean.
 Wear a dust protection mask when maintaining and
cleaning the vacuum cleaner.
If the replacement of the supply cord is necessary, this has to
be done by Bosch or an authorized Bosch service agent in or-
der to avoid a safety hazard.
A dust-technical inspection is to be carried out at least once
every year by the manufacturer or an instructed person, e. g.
for damage of the filter, tightness against leakage of the vacu-
um cleaner and function of the control/monitoring unit.
For category M vacuum cleaners that were in contaminated
environments, the exterior as well as all machine parts should
be cleaned or treated with sealants. When performing mainte-
nance and repair work, all contaminated components that
cannot be cleaned to satisfactory must be disposed of. Such
components must be disposed of in impermeable plastic bags
conforming with the valid regulations for the disposal of such
waste.
For maintenance on behalf of the user, the vacuum cleaner
must be disassembled, cleaned and maintained as far as fea-
sible, without causing a risk for the maintenance personnel or
other persons. Prior to disassembly, the vacuum cleaner
should be cleaned in order to prevent any risks. The room/en-
closure in which the vacuum cleaner is disassembled should
Bosch Power Tools
be well ventilated. Wear personal protective equipment dur-
ing maintenance. After the maintenance, the maintenance ar-
ea should be cleaned.
Removing/Replacing the Flat-fold Filter
(see figures J1 –J2)
Replace a damaged flat-fold filter 30 immediately.
– Pull the locking latch 20 and open the filter cover 39.
– Grasp the flat-fold filter 30 by the fins, pull up and remove.
– When taking out the flat-fold filter 30, remove any accumu-
lating dust and debris from the closing edge of the filter
cover 39 using a moist cloth.
– Gently strike/tap out the flat-fold filter 30.
PES and PTFE flat-fold filters can be flushed out under run-
ning water.
– Insert a new or the cleaned flat-fold filter 30; observe prop-
er and tight seating.
– Shut the filter cover 39 again (must be heard to engage).
Container
– Wipe out the container 1 from time to time with a commer-
cially available, non-scouring cleaning agent and allow to
dry.
Level Sensors (see figure K)
Clean the level sensors 40 occasionally.
– Unlock the latches 15 and remove the vacuum lid 13.
– Clean the level sensors 40 with a soft cloth.
– Reattach the vacuum lid 13 again and lock the latches 15.
Storage (see figure L)
– Wind the mains cable around the cable holder 14.
– Insert the accessories into the holders provided: Vacuum
tubes 35 in holders 22, crevice nozzle 31 in holder 21,
floor nozzle 34 in holder 24.
– Undue the elastic tie-downs of the vacuum-hose holders 4
and place the vacuum hose 27 around the vacuum cleaner
lid into the holders 4.
Reattach the elastic tie-downs.
– Mount the L-Boxx onto the retainers 11.
– For transport of the vacuum cleaner, screw the plug cap 2
onto the hose connection piece 3.
– Store the vacuum cleaner in a dry room and secure it
against unauthorised use.
– To lock the castors 18, actuate the castor brakes 17 by
pushing down.
Transport (see figure M)
– Carry the vacuum cleaner only by the carrying handle 10.
– Use the push handle 12 for moving the VAC around or pull-
ing it over edges or obstacles.
English | 23
1 619 929 L62 | (15.2.13)

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

0.601.9c3.300

Table des Matières