Do not point the air outlet of blow nozzle at a person.
Do not use the blow nozzle with the push lever left fit.
This Nailer has a blow nozzle that blows out wood
shavings which occur during work.
Press the knob with your thumb to use the blow nozzle
(See Fig. 10).
NOTE
When the blow nozzle is used for a long time, the
nailing force may degrade temporarily. In this case,
allows the air supply pressure to stabilize before
starting work.
Oil in the body or drained water from the compressor
can sometimes spout out of the air outlet of blow
nozzle. It is recommended that you once conduct a
test before use and see if such phenomenon happens
at an environment where spouted oil will cause any
inconvenience.
4. Changing the exhaust direction
The direction of the exhaust vent can be changed by
turning the top cover (See Fig. 11).
5. Using the nose cap (See Fig. 12)
The nose cap is attached to the push lever tip to
protect the workpiece from scratches or damage.
Remove in the order shown below when not using.
(1) DISCONNECT AIR HOSE FROM NAILER.
(2) Put the nose cap to the tip of the push lever.
Attach to the tip of the push lever in the reverse order
of detaching.
NOTE
The nose cap may reduce nailing depth due to its
thickness. Re-adjustment of nailing depth is required.

INSPECTION AND MAINTENANCE

CAUTION
Be sure to disconnect the hose during cleaning
jams, inspection, maintenance and cleaning.
1. Countermeasure for nail jamming
(1) DISCONNECT AIR HOSE.
(2) Remove all nails.
(3) Release the lock lever and open guide plate (A) (See
Fig. 13).
(4) Remove the jammed nail with a slotted-head
screwdriver (See Fig. 14).
(5) Close guide plate (A) and latch.
(6) In case of frequent jams, consult the Authorized
Service Center from which you bought this machine.
2. Inspecting the magazine
Clean the magazine. Remove dust or wooden chips
which may have accumulated in the magazine. Apply
oil occasionally to the nail rail (See Fig. 15).
3. Check on mounting screws for each part
At regular intervals check every part for loose
mounting screws and whether or not there are any
air leaks. Retighten any loose screws. Operating the
equipment with loose screws untightened will incur
a hazard.
4. Inspecting the push lever
Check if the push lever (Fig. 1) can slide smoothly.
Clean up the sliding area of the push lever and use
the provided oil for lubrication from time to time.
Lubrication
enables
simultaneously serves to prevent the formation of
rust.
smooth
sliding
and
5. Storing
When not in use for an extended period, apply a thin
coat of the lubricant to the steel parts to avoid rust.
Do not store the Nailer in a cold weather environment.
Keep the Nailer in a warm area.
When not in use, the Nailer should be stored in a
warm and dry place.
Keep out of reach of children.
6. Service parts list
A: Item No.
B: Code No.
C: No. Used
D: Remarks
CAUTION
Repair, modification and inspection of Hitachi Power
Tools must be carried out by a Hitachi Authorized
Service Center.
This Parts List will be helpful if presented with the
tool to the Hitachi Authorized Service Center when
requesting repair or other maintenance.
In the operation and maintenance of power tools, the
safety regulations and standards prescribed in each
country must be observed.
MODIFICATION
Hitachi Power Tools are constantly being improved
and modified to incorporate the latest technological
advancements.
Accordingly, some parts (i.e. code numbers and/or
design) may be changed without prior notice.
COMPRESSOR
CAUTION
When the maximum, operating pressure of the air
compressor exceeds 8.3 bar (120 psi.), be sure to
provide a reducing valve between the air compressor
and nailer. Then, adjust the air pressure within the
operating range of 4.9 – 8.3 bar (70 – 120 psi.). If the
air set is installed, lubrication is also possible, thus
providing additional convenience.
OILER-FILTER-REDUCING VALVE (Air Set)
So that the equipment can be operated under an optimum
condition to ensure extended service life, it is
recommended to use an oiler filter reducing valve. Please
limit the length of the hose between the unit and the air
set to within 10 m when using (See Fig. 16).
APPLICABLE LUBRICANTS
Type of lubricant
Recommended oil
Motor oil
Turbine oil
English
Name of lubricant
SHELL TONNA
SAE10W, SAE20W
ISO VG32 – 68
(#90 – #180)