Technical Description; Control Elements; Mounting The Mains Rectifier - Dometic CoolPower EPS100 Instructions De Montage Et De Service

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 21
EPS100
5

Technical description

The mains rectifier can operate all coolers and refrigerators with BD35F compressors
at 230 V. With a 230 V mains connection, the rectifier automatically switches from
battery to mains operation.
When disconnected from the 230 V mains supply, the rectifier automatically
switches back to battery operation. Mains operation via the rectifier always takes
priority over battery operation.
5.1

Control elements

Item in
fig. 1,
Explanation
page 3
1
Mains cable
2
Fastening bracket
3
Self-tapping screws
4
12 V socket
5
Glass fuse (250 V, 12 A, slow-blow)
6
Compressor output terminals
7
Battery input terminals
6

Mounting the mains rectifier

If you wish to mount the mains rectifier in a fixed position, please observe the
following mounting instructions:
• Do not mount the device
– In wet or damp environments
– In the vicinity of combustible materials
– In areas where there is a danger of explosions
• The place of installation must be well-ventilated. A ventilation system which is at
least equivalent to the air openings in the device must be present for installations
in closed housings.
• The air intake on the underside or the air outlet on the back of the device must
remain clear.
• The installation surface must be level and sufficiently sturdy.
EN
Technical description
9

Publicité

Table des Matières
loading

Table des Matières