(for example, while taking a bath or shower). Do not immerse the device in water; in
the event of immersion immediately disconnect the plug. Do not remove or touch the
immersed device; unplug the power cable first. Immediately bring the device to an
authorised FLAEM service centre or to your trusted dealer.
• Use the device only in dust-free conditions, otherwise treatment could be compromised.
• The device casing is not waterproof. Do not wash the device under running water or by
immersion and keep it safe from being sprayed by water or other liquids.
• Do not expose the device to particularly extreme temperatures.
• Do not place the device near sources of heat, in direct sunlight or in excessively hot
rooms.
• Do not obstruct or put objects into the filter or its related housing in the device.
• Never obstruct the air vents located on both sides of the device.
• Always use it on a rigid surface that is clear of obstacles.
• Make sure there is no material obstructing the air vents before each use.
• Do not put any objects in the air vents.
• Repairs must be carried out only by FLAEM authorised personnel. Unauthorised repairs
void the warranty and may be hazardous for the user.
• The average expected duration for the compressor series are: F400: 400 hours, F700:
700 hours, F1000: 1000 hours, F2000: 2000 hours.
• WARNING: Do not modify this device without authorisation from the manufacturer.
• The Manufacturer, the Vendor and the Importer shall be held responsible for safety,
reliability and performance only if: a) the device is used in compliance with the
instructions for use b) the wiring where the device is being used is in compliance with
safety regulations and current laws.
• Interactions: the materials used in contact with medication have been tested with a
vast range of medications. However, in view of the variety and continuous evolution
of pharmaceuticals, interactions cannot be ruled out. We recommend using the
medication as soon as possible once it has been opened and preventing prolonged
exposure in the nebuliser cup.
• The manufacturer must be contacted to report problems and/or unexpected events
related to operation.
OPERATING INSTRUCTIONS
Before each utilisation, wash your hands accurately and clean the device as described
in the paragraph "CLEANING, SANITISATION, DISINFECTION AND STERILISATION".
The nebuliser cup and accessories are for personal use only to avoid potential risks of
transmitting infection.
During application it is advisable to suitably protect yourself from any dripping.
1. Plug the power cable (A7) into mains socket that is compatible with the device voltage.
The position of the socket must be such that the device can be easily unplugged from the
mains network.
2. Insert the nozzle (C1.2) in the upper part (C1.3) pressing as shown by the 2 arrows in the
"Connection diagram" in point C1. Insert the Speed selector with valve (C1.4) in the up-
per part (C1.3) as shown in the "Connection diagram" in point C1. Pour the medication
prescribed by the doctor into the lower part (C1.1). Close the nebuliser by turning the
upper part (C1.3) clockwise.
3. Connect accessories as indicated in the "Connection diagram" on the cover.
4. Sit comfortably holding the nebuliser in your hand, place the mouthpiece onto your
mouth or alternatively use the nose piece or mask. Should you opt for the mask acces-
10