Technical Data

Version
Model
Pressure ratio
Interior container diameter (mm)
Max. container height (mm)
Outlet pressure (media) at a working pressure of 6 bar (bar)
Outlet pressure (media) at a working pressure of 10 bar (bar)
Min. / Max. working pressure (bar)
Pumping volume per double stroke (cm
Pump delivery volume at the outlet (cm
Max. air consumption (l/min)
Internally threaded connection (compressed air)
Externally threaded connection (media)

Assembly / Installation

The product is to be set up or installed at the inten-
ded use site under due consideration of the following
conditions:
• At the location and site all applicable provisions of
law must be clarified and compliance with them
assured.
• The ground and space relations are to be clarified
prior to set-up/installation of the product in order
to assure safe operation for the personnel and the
product long-term. The product must be set-up/
installed so that safe, permanent operation is
assured.
• The product may only be set up and commissioned
by specially trained technicians.
• The product is constructed for rooms that are
protected from the influence of the weather
(industry standard).
• The operation and storage in aggressive or humid
environments or outdoors can lead to corrosion
damages.
)
3
/min.)
3

Commissioning

The system was fully tested before delivery and set to
the previously specified container size, if known.
1. Remove all packaging from the system before
commissioning.
2. Turn the rotary switch (Figure D/no. 18) to Hold .
3. Connect the system to the compressed air supply
(Figure B/no. 12).
4. Check the air pressure at the pressure gauges.
Verify that the network pressure is adequate.
1 - 5 kg
1 - 5 kg
Type S
Type S
10:1
25:1
80 - 250
80 - 250
285
285
60
140
100
233
4/10
4/10
16
17
1720
1295
150
217
G 1/4"
G 1/4"
G 1/4"
G 1/4"
NOTE
Ensure that all screws and hoses
are tightened properly (leaks).
NOTE
The control pressure of the pneu-
matic switching system is set to
4 bar at the factory. Attention: Do
not adjust!
The pump pressure is set to 4 bar at
the factory.
The follower plate application pressu-
re is set to 0.5 bar at the factory.
To adjust the pump lifter pneumatic
cylinder pressure, pull the adjustment
knob and
 to the right = increase the pressure
 to the left = reduce the pressure
EN
1 - 5 kg
Type S
60:1
80 - 250
285
335
555
4/10
7.5
465
217
G 1/4"
G 1/4"
21

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Axfp1-s25Axfp1-s60Axfp1-s10

Table des Matières