MCA1215 – MCA2440
➤ Use the DIP switches (fig. a page 7) to set the required functions and
values:
– To set the switchover voltage:
Switch 1
ON
OFF
– To set the retention voltage:
Switch 2
ON
OFF
– To set the power mode:
Switch 1
OFF
OFF
ON
– Enabling the control for external devices (such as MPC01, does not
apply to MCA-RC1):
Switch 1
ON
– To activate sleep mode:
Switch 4
ON
EN
Switch 3
OFF
OFF
Switch 3
OFF
OFF
Switch 2
Switch 3
OFF
ON
ON
ON
OFF
ON
Connecting the device
Switchover voltage
14.4 V / 28.8 V
14.7 V / 29.4 V
Retention voltage
13.5 V / 27.0 V
13.8 V / 27.6 V
Constant voltage
MCA12..
13.2 V
13.8 V
14.4 V
Switch 2
ON
MCA24..
26.4 V
27.6 V
28.8 V
Switch 3
ON
57